Product
Index :: Safety Solutions ::
Application Controllers
|
|
F3SX
Safety Controller
|
|

|

|
* Ordering information
* Specifications
* Configurations
* Dimensions, and etc
|
|
can be found in our PDF brochure.
|
|
Safe, Simple and Visible
Safety Controller with No Programming
Conforms to global safety standards.
All-in-one constructions for easy
multi-input safety circuits.
Information where you need it: LED
indicators, auxiliary outputs, and serial communications.
|
|
What is
Safety Controller? |
|
Are Your Safety Inputs
Connected to Your PLC Built with Interlocks?
Generally, safety is jeopardized in PLCs and other programmable control
devices due to partial memory loss, CPU runaways, and situations such as
on-site overwriting of programs. Using Safety Light Curtains and Safety
Door Switches on their own does not necessarily ensure sufficient safety
for PLC operation. Nor is safety fully secured through the use of relays
in interlocks due to hazardous events that occur as a result of fused
relays or short-circuited wiring.
The F3SX offers safety and simple connections for an array of safety
equipment, such as Safety Light Curtains and Safety-door Switches,
functioning as a central hub to perform integrated monitoring of various
safety equipment.

|
|
Configuration |
|
The Modular Configuration
Fits Your Equipment Perfectly. An All-in-one Solution for Delivering
Required I/O


Note
1: Up to four sets of F3SN-A/B Safety Light Curtain/F3SH Multi-beam Safety
Sensors can be supplied power from the F3SX. Consider this factor when
selecting and wiring the Safety Controller. Up to four Modules can be
connected if the Safety Light Curtains/Multi-beam Safety Sensors are
supplied power directly from an external power supply.
2. To set the delay time, use the Function Setup Software for the F3SX or
specify a model with the T[][][] suffix.
|
|
Safe! |
|
The Safety Controller
Complies with Global Safety Standards
In addition to International standards (IEC), the F3SX also conforms to
European (EN), and U.S./Canadian (UL) safety standards, enabling
trouble-free use in machinery for Europe, the U.S. and Canada.
Applicable Standards:
-
European Machinery Directive 98/37/EC, Low
Voltage Directive 73/23/EEC
-
IEC 61508 1998 (EN 61508 2001) (SIL 1-3)
-
EN 954-1 1996 (Category B 1-4)
-
EN 50178 1997, UL 508, UL 1998, etc.

Technology-backed Safety
Design
We pursued safety to the limit to deliver
safety and reliability backed by the highest level of safety design and
FMEA. Two CPU Units perform mutual checking and diagnostic monitoring of
each I/O section, and the safety of operations is further verified by FMEA
and process-controlled design and production.

|
|
Simple |
|
Connection is Easy Using
Plug-in Connectors for Even More Readily Accessible Safety

-
No unnecessary wiring between Units allows
considerable cuts in the cost of evaluating design safety.
-
Reduced wiring, post terminals, and
connector connections enable substantial reductions in the cost of
maintenance labor.
-
Width has been reduced by 50% from 225 mm
to 112.5 mm max. (compared to
previous OMRON products; connecting F3SN (4 sets), F3SP-B1P, and
G9SB-301).
-
Post terminals aid in preventing
unintentional neglect to tighten terminal screws.
-
Convenient F39-TB01 Junction Box for
Safety Light Curtain. Using the Connector Cables specially designed for
Safety Light Curtains/Multibeam Safety Sensors and a Junction Box for
Safety Light Curtain makes for efficient wiring to a Control Box
installed at a distance.

|
|
Visible |
|
Providing Meaningful Safety
Equipment information that Satisfies Needs for Safety and Peace of Mind

Previously: Majority of
time lost due to failures is from investigating the causes. In particular,
most time is spent in determining the location of broken lines or faulty
contacts.
Using F3SX: Shorter Downtimes!
Indicator displays are easy to
understand and more convenient. The F3SX uses indicators to show the
status of each I/O, contributing to less time (downtime) spent
investigating the cause.


|
|
Application |
|
Applications Using
Electromagnetic Lock Switches and Safety Light Curtains for Detecting
Workers

Simple External Stop Input Connection
When an electromagnetic lock and Safety Light Curtain (worker detection)
are used, as shown in the diagram, an external stop command input is
required in addition to the Emergency Stop Switch.
Inputting a PLC operation command to the SSC input allows easy connection
and control. Causes of failures can be determined from detailed
communications data, which safeguards against any problem that may occur.
Indicator Lighting Pattern Shows Lock
Release Timing to Operator
External indicator output lighting patterns can be utilized as work
permission indicators. When equipment stops, the indicator turns ON.
During OFF delays, indicator flashing gradually increases speed as the
remaining time shortens to notify the operator of release timing. This
contributes to increased productivity and dispels agitation due to unknown
waiting times.

|
top |
See Related Products:

|
Safety Light
Curtain
F3SJ
Simple. Easy to use. The new
standard in Safety Light Curtains. |

|
Emergency Stop
Switch
A22E
Safety lock mechanism, install in
22-dia. or 25-dia. panel cutout that prevents misuse. |

|
Guard Lock
Safety-door Switch
D4NL
Lead-free, environment-friendly
Guard Lock Safety-door Switch. |
|
|
 |
|