* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: May 23, 2013
| Model | Standard Models
E2SS-M Series |
Magnetic Field Immune Models *
E2SS-W Series |
|||
|---|---|---|---|---|---|
| E2SS-MC1(-M1J) | E2SS-MB1(-M1J) | E2SS-WC1-P1 | E2SS-WB1-P1 | ||
| Power supply voltage | 10 to 30 VDC (including ripple (p-p): 10 %) | ||||
| Detection sensitivity
(magnetic sensitivity) |
2.8 mT max. | ||||
| Current consumption | 15 mA max. | ||||
| Hysteresis | 1 mm max. | ||||
| Repeat accuracy | ±0.1 mm max. | ||||
| Pass speed | 10 m/s max. | 1 m/s max. | |||
| Switching frequency | 1 kHz max. | 20 Hz max. | |||
| Control
output |
Switching
capacity |
150 mA max. | 100 mA max. | ||
| Residual
voltage |
2 V max.
(Load current: 150 mA, Cable length: 2 m) |
2 V max.
(Load current: 100 mA, Cable length: 2 m) |
|||
| Indicator | Operation indicator (yellow) | ||||
| Operation mode | NPN open-collector,
NO (normally open) |
PNP open-collector,
NO (normally open) |
NPN open-collector,
NO (normally open) |
PNP open-collector,
NO (normally open) |
|
| Protective circuits | Power supply reverse polarity protection, output reverse polarity protection, and load short-
circuit protection |
||||
| Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
| Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between charged parts and case | ||||
| Dielectric strength | 500 VAC, 50/60 Hz for 1 min between charged parts and case | ||||
| Vibration resistance
(endurance) |
10 to 55 Hz with 1.0-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance
(endurance) |
300 m/s2 10 times each in X, Y, and Z directions | ||||
| Degree of protection | IEC 60529 IP67 | ||||
| Connection method | Blank: Pre-wired (standard cable length: 2 m)
-M1J: Pre-wired M12 connector (cable length: 0.3 m) |
M12 connector | |||
| Weight (when packed) | Pre-wired models: Approx. 35 g
Pre-wired M12 connector models: Approx. 30 g |
Approx. 25 g | |||
| Materials | Case: PP, Cable: PUR | Case: PA, Connector: PA | |||
| Accessories | Instruction Manual, cable clip (one) | Instruction Manual, mounting screw (one) | |||