IO-Link Proximity Sensor (Standard Models)
last update: September 12, 2016
Item | Size | M12 | M18 | M30 |
---|---|---|---|---|
Shielded | Shielded | |||
Model | E2E-X3B4-IL[] | E2E-X7B4-IL[] | E2E-X10B4-IL[] | |
Sensing distance | 3 mm ±10% | 7 mm ±10% | 10 mm ±10% | |
Set distance *1 | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 8 mm | |
Differential travel | 10% max. of sensing distance | |||
Detectable object | Ferrous metal
(The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) |
|||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
Response frequency *2 | 1 kHz | 0.5 kHz | 0.4 kHz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)) | |||
Current consumption | 20 mA max. | |||
Control output | Load current | 100 mA max. | ||
Residual voltage | 2 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Indicators *1 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability
indicator (green, lit) In the IO-Link mode: Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
|||
Operation mode | PNP NO/NC switching type (Factory setting: NO)
Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
|||
Protection circuits | Power supply reverse polarity protection, output reverse polarity protection, surge
suppressor, and output short-circuit protection |
|||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
|||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant *3 | |||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m) |
|||
Materials | Case | Nickel-plated brass | ||
Sensing surface | PBT | |||
Clamping nuts | Nickel-plated brass | |||
Toothed washer | Zinc-plated iron | |||
Main IO-Link functions | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, and initial reset |
|||
Communication
specifications |
IO-Link
specification |
Ver 1.1 | ||
Baud rate | -IL3: COM3 (230.4 kbps), -IL2: COM2 (38.4 kbps) | |||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | |||
Minimum cycle
time |
-IL3 (COM3): 1 ms, -IL2 (COM2): 2.3 ms | |||
Accessories | Instruction manual |
Note: Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).
*1. In the Standard I/O mode (SIO mode), use the product in a range that the green stability indication lamp is lit. (Although the lamp is turned off when the object detected has approached excessively, the detection performance is stable.)
In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.) Please contact your OMRON sales representative regarding assignment of data.
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. Oil resistance in-house standard: Performance with respect to water insoluble oil.
(Test at below)
After the test time elapses, the characteristics below are checked for problems.
(1) Visual appearance (no damage that affects product characteristics)
(2) Operation check (ON/OFF) (3) Insulation resistance (50 MΩ min. at 500 VDC)
(4) Dielectric strength (500 VAC, 1 min.)
(5) Water resistance (IP67)
last update: September 12, 2016