F3SX
Safety Controller |
|
Detects two wires shorted together with the self-diagnosis
function and specifies the location of the problem with the
communications function.
Tell I/O status at a glance from LED indicators.
Conforms to safety category 4 and SIL 3.
Controls up to four light curtain sets.
|
4 (EN954-1)
SIL3
(EN61508) |
EN/IEC61508
EN954-1
EN61000-6-2
EN61000-6-4
EN/IEC61496-1
EN/IEC60204-1
EN50178
EN55011
UL508
UL1998 |
TÜV Product Service
UL (cUL)
KOSHA *1
|
|
G9SX
Flexible Safety Unit |
|
Logical AND connection enables partial or full control.
Uses solid-state output (excluding Expansion Units).
LED indicators provide details of failure diagnosis.
|
4 (EN954-1)
SIL3
(EN61508) |
EN50178
EN954-1
IEC/EN60204-1
IEC/EN61508
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
CAN/CSA C22.2 No.142 |
TÜV Product Service
UL
|
|
G9SX-GS
Safety Guard
Switching Unit |
|
Auto Switching and Manual Switching functions support two types
of application.
External indicator outputs enable indicating the switching
status of two safety input devices.
Auxiliary outputs enable monitoring of safety inputs, safety
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in
combination with other G9SX-series Units.
|
4
(EN954-1)
SIL3
(IEC/
EN61508,
IEC/
EN62061) |
EN50178
IEC/EN60204-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
IEC61508
CAN/CSA C22.2
No.142 |
TÜV Product Service
UL (cUL)
|
|
F3SP-U2P
Safety Sensor Muting
Controller |
|
Adds muting function to Safety Sensors.
Connects to a maximum of 2 Safety Sensors.
|
4 (connected to Type 4 Sensors)
2
(connected to Type 2 Sensors) |
IEC61496-1 |
TÜV Product Service
UL (cUL)
|
|
G9SA-300-SC
Safety Relay Unit
(Sensor Connector Type) |
|
Sensor connectors allow direct connection to F3SN-A, F3SN-B and
F3SH-A.
Reduces wiring and prevents incorrect connection.
Connection to emergency stop switch also supported.
|
4 (connect with F3SN-A/ F3SH-A)
2 (connect with F3SN-B) |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 |
TÜV, Rheinland
UL
CSA
|
|
G9SA
Safety Relay Unit |
|
Compact design.
Two-hand Controller model available.
Simple connection of Expansion Unit.
High-speed 10-ms response.
Incorporates LED indicators for monitoring built-in relays.
Finger protection construction.
3-pole, 5-pole and Off-delay Units available.
|
4
3
(OFF-relay contact) |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 |
BG
UL
CSA
|
|
G9SB
Safety Relay Unit |
|
Ultra-compact, with models starting at only 17.5 mm wide.
Can be used with Safety Sensors.
High-speed 10-ms response.
Incorporates LED indicators for monitoring built-in relays.
Finger protection construction.
|
4
3 (*2) |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 |
TÜV, Rheinland
UL
CSA
|
|
G9S
Safety Relay Unit |
|
Two-pole, three-pole, five-pole, and OFF-delay models are
available.
Incorporates LED indicators for monitoring built-in relays.
Finger-protection construction.
|
4
3
(OFF-relay contact) |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 |
BIA
UL
CSA
|
|
CQM1-SF200/ CS1W-SF200
Safety Relay Unit |
|
PLC I/O Unit-type safety relay.
Can be used with OMRON PLC models CQM1H and CS1.
The monitor signal of the safety circuit connects directly to
the CPU of the PLC through the internal bus.
Simplified wiring and space-saving construction.
|
4 |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 |
TÜV, Rheinland
UL
CSA
|