Question

What is the life span of the coils when voltage is continuously applied to coils for MY2 AC100V General-purpose Relays?

Answer

The general heat-resisting life span for the wire is 40,000 hours. Therefore, if polyurethane copper wire is used in the coil, the life of the coil is approximately 5 years. (A life of 5 years is applicable when applying the rated voltage in a normal environment.)