UL Certification for Industrial Components
Timers
|
Model |
Input Ratings |
Standard No. |
File No. |
Marking |
Listed/ Recognized |
Category |
|
H2C |
24, 48, 100, 110, 115, 120, 200, 220, 230, 240V AC |
UL917 |
E52800 |
RU |
Recognized |
WGZR2/WGZR8 |
H2F |
100 to 120, 200 to 240, 100 to 240V AC |
H3AM |
100 to 240V AC |
UL508 |
E41515 |
RU |
Recognized |
NRNT2/NRNT8 |
|
H3CA |
24 to 240V AC12 to 240V DC |
|
H3CR-A |
100 to 240V AC/100 to 125V DC 24 to 48V AC/12 to 48V DC 24 to 48V AC/DC |
|
H3CR-F |
100 to 240V AC, 12V DC, 24V AC/DC, 48 to 125V DC, 24V DC |
|
H3CR-G |
100/110/120V AC, 200/220/240V AC |
|
H3CR-H |
100/110/120V AC, 200/220/240V AC, 24V AC/DC, 48V DC, 100 to 125V DC |
|
H3DK |
24 to 240V AC/DC,
100 to 120V AC, 200 to 240V AC, 24 to 48V AC/DC, 12V DC |
uRUus |
|
H3DS-AL |
24 to 230V AC |
RU |
|
H3DS-ML H3DS-SL H3DS-FL H3DS-GL |
24 to 48V DC |
|
H3DS-XL |
24 to 230V AC/DC |
H3FA |
5, 6, 12, 24V DC 5/6, 12/24V DC (models ending in "-S") |
H3M |
24, 48, 100/110/120, 200/220/240V AC 12, 24, 48, 100, 110, 125V DC |
|
H3RN |
24V AC, 12, 24V DC |
H3Y |
24, 42, 48, 100 to 120, 200 to 230, 240V AC 12, 18, 24, 48, 100 to 110, 125V DC (models ending in "-S": 24 VDC only) |
H3YN |
24, 100 to 120, 200 to 230V AC 12, 24, 48, 100 to 110, 125V DC |
H5AN |
24V AC, 100 to 240V AC 12 to 24V DC, 48V DC, 100V DC |
H5CN |
24V AC, 100 to 240V AC 24V DC, 12 to 48V DC, 100/110V DC |
|
H5CX
H5CZ |
100 to 240V AC, 24V AC, 12 to 24V DC |
cULus
uRUus |
Listed
Recognized |
NRNT/NRNT7 (models with
terminal blocks)
NRNT2/NRNT8 (models with pins) |
H5F |
100 to 240V AC |
cULus |
Listed |
NRNT/NRNT7 |
H5L |
100 to 240V AC |
UL917 |
E52800 |
RU |
Recognized |
WGZR2/WGZR8 |
H5S |
100 to 240V AC, 24V DC |
UL508 |
E41515 |
uRUus |
Recognized |
NRNT2/NRNT8 |
Note:
Field wiring for H5CX-series and H5CZ-series
Counters with pins is enabled by using a P2CF-08 (P2CF 08-E, P2CF-11, or
P2CF-11-E) Socket from OMRON or an equivalent socket.
Counters
|
Model |
Input Ratings |
Standard No. |
File No. |
Marking |
Listed/
Recognized |
Category |
|
H7AN |
24V AC, 100 to
240V AC
12 to 24V DC |
UL508 |
E41515 |
RU |
Recognized |
NRNT2/NRNT8 |
|
H7BX |
100 to 240V AC,
24V AC, 12 to 24V DC |
H7CN |
24V AC, 100 to
240V AC
24V DC, 12 to 48V DC, 100/110V DC |
|
H7CX
H7CZ |
100 to 240V AC
24V AC/12 to 24V DC
12 to 24V DC |
cULus
RU |
Listed
Recognized |
NRNT/NRNT7 (models with
terminal blocks)
NRNT2/NRNT8 (models with pins) |
|
H7E-N
|
24 to 240V AC/DC (models
ending in "-FV")
4.5 to 30V DC (models ending in "-V")
3V DC (models ending in "-P") |
UL863 |
E67871 |
RU |
Recognized |
ELIY2 |
|
H7GP
H7HP |
100 to 240V AC, 12 to 24V
DC |
UL508 |
E41515 |
RU |
Recognized |
NRNT2/NRNT8 |
|
H8BM-R |
24V DC |
|
H8GN |
24V DC |
Note:
Field wiring for H7CX-series and H7CZ-series
Counters with pins is enabled by using a P2CF-08 (P2CF 08-E, P2CF-11, or
P2CF-11-E) Socket from OMRON or an equivalent socket.
Cam Positioners
|
Model |
Input Ratings |
Standard No. |
File No. |
Marking |
Listed/
Recognized |
Category |
|
3F88L-160/162 |
100 to 240V AC |
UL508 |
E95399 |
cULus |
Listed |
NRAQ/NRAQ7 |
|
H8PS |
24V DC |
UL508 |
E41515 |
cULus |
Listed |
NRNT/NRNT7 |
Note: The above table lists series names. Ask your
OMRON representative for details on specific model numbers.
Temperature Controllers
|
Model |
Input Ratings |
Standard No. |
File No. |
Marking |
Listed/ Recognized |
Category |
|
E5AN
E5CN
E5EN
E5GN |
100 to 240V AC
24V AC/DC |
UL61010-1 |
E316989
|
cULus |
Listed |
QUYX/QUYX7 |
E5AR E5ER |
100 to 240V AC
24V AC/DC |
UL61010C-1 |
E200593
|
cRUus |
Recognized |
QUYX2/QUYX8 |
E5[]R-T |
100 to 240V AC
24V AC/DC |
UL61010C-1 |
E200593
|
cRUus |
Recognized |
QUYX2/QUYX8 |
|
E5C2 |
100 to 120V AC
200 to 240V AC |
UL61010C-1 |
E200593 |
RU |
Recognized |
QUYX2 |
|
E5CN-U |
100 to 240V AC
24V AC/DC |
UL61010-1 |
E316989
|
cULus (with P2CF-11) |
Listed |
QUYX/QUYX7 |
|
E5CS-U |
100 to 240V AC
24V AC/DC |
UL61010C-1 |
E200593
|
cULus (with P2CF-08 or with
P2CF-11) /cRUus(E5CS-U only) |
Listed/
Recognized |
QUYX/QUYX7 QUYX2/QUYX8 |
|
E5CSV |
100 to 240V AC
24V AC/DC |
UL61010-1 |
E316989
|
cULus |
Listed |
QUYX/QUYX7 |
E5ZN (excluding the E5ZN-DRT) |
24V DC |
UL61010C-1 |
E200593
|
RU |
Recognized |
QUYX2 |
|
E5ZN-DRT |
24V DC |
UL508 |
E95399 |
cRUus |
Recognized |
NRAQ2/NRAQ8 |
|
EJ1 |
24V DC |
UL61010C-1 |
E200593
|
cRUus |
Recognized |
QUYX2/QUYX8 |
K8AB-TH |
24V AC/DC
100-240V AC |
UL61010-1 |
E200593 |
--- |
Digital
Panel Meters
Signal Converters
|
Model |
Input Ratings |
File No. |
|
K3SC |
100 to 240V AC, 24V AC/DC |
E95399 |
Programmable Relays
|
Model |
Input Ratings |
Standard No. |
File No. |
|
ZEN |
100 to 240V AC
24V DC |
UL508 |
E95399 |
|
ZEN-PA |
100 to 240V AC |
UL508 |
E104818 |
|
UL1604 |
E198998 |
|
UL60950-1 |
E152784 |
Level Controllers
|
Model |
Input Ratings |
File No. |
|
61F-GN |
100/200, 110/220,
120/240V AC |
E138234 |
|
61F-G1N |
|
61F-G2N |
|
61F-G3N |
|
61F-G4N |
|
61F-IN |
|
61F-GPN-V50 |
24, 100, 110,
120, 200, 220, 230, 240V AC |
|
61F-GP-N8 |
100, 110, 120, 200, 220,
240V AC |
|
61F-D21T-V1 |
24V AC/DC, 100-240V AC |
|
61F-GPN-B |
24V DC |
E200593 |
Liquid Leakage Sensors
Basic
Switches
|
Model |
Input Ratings |
Standard No. |
File No. |
|
Z-01H |
0.1A 30V DC
(Resistive)
0.1A 125V AC (General Use) |
UL508 |
E41515 |
|
Z-10F |
0.6A 125V, 0.3A
250V DC (Resistive)
6A 125V, 6A 480V AC (General Use)
1/10HP 125V, 1/6HP 250V AC (power rating) |
Parallel Circuit
Connection |
|
Z-10G |
0.5A, 125V DC,
0.25A 250V DC (Resistive)
10A 250V AC (General Use) |
|
Z-15 |
0.5A 125V, 0.25A
250V DC (Resistive)
15A 125V, 15A 250V, 15A 480V AC (General Use)
1/8HP 125V, 1/4HP 250V AC (power rating) |
|
A-20G |
0.5A 125V, 0.25A
250V DC (Resistive)
20A 125V, 20A 250V, 20A 480V AC (General Use)
1HP 125V, 2HP 250V AC (power rating)
10A 125V AC (Lamp load) |
|
X-10G |
10A 125V, 3A 250V
DC (Resistive) |
|
DZ-10G |
0.5A 125V, 0.25A
250V DC (Resistive)
10A 125V, 10A 250V, 2A 480V AC (General Use)
1/8HP 125V, 1/4HP 250V AC (power rating) |
Note:
1. Certification is obtained with representative
models. Ask your OMRON representative for details on the standards.
2. The model with a rating of 100,000 operations
is different from the standard model. Specify the desired model when ordering.
3. The applicable standard number is given in the
Standard No. column. The certification report number is given in the File No.
column.
Limit
Switches
|
Model |
Ratings |
Standard No. |
File No. |
|
WL |
A600(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A 480V
AC: Make: 15A, Break: 1.5A 600V AC: Make: 12A, Break: 1.2A Max. VA:
Make: 7,200VA, Break: 720VA |
UL508 |
E76675 |
WL-LE |
A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A Max.
VA: Make: 7,200VA, Break: 720VA |
WL-LD |
A150 (Carry
current: 10 A):
120 V AC: Make: 60 A, Break: 6.0 A
Max. VA: Make: 7,200 VA, Break: 720 VA10A 115V AC, 0.8A 115V DC |
WL01 |
0.1A 125V AC, 0.1A 30V DC |
WL01-LE |
0.1A 125V AC |
WL01-LD |
0.1A 115V AC, 0.1A 30V DC |
D4A-01 (SPDT, double-break,
without indicator) |
A600(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A 480V
AC: Make: 15A, Break: 1.2A 600V AC: Make: 12A, Break: 1.2A Max. VA:
Make: 7,200VA, Break: 720VA |
D4A-03 (SPDT, double-break,
with neon lamp) |
A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A Max.
VA: Make: 7,200VA, Break: 720VA |
D4A-05 (DPDT, double-break,
simultaneous operation)
D4A-07 (DPDT, double-break,
sequential operation)
D4A-09 (DPDT, double-break,
center neutral operation) |
B600(Carry current: 5A):
120V AC: Make: 30A, Break: 3.0A 240V AC: Make: 15A, Break: 1.5A 480V
AC: Make: 7.5A, Break: 0.75A 600V AC: Make: 6.0A, Break: 0.60A Max.
VA: Make: 3,600VA, Break: 360VA |
D4C (without indicator) |
B300(Carry current: 5A):
120V AC: Make: 30A, Break: 3.0A 240V AC: Make: 15A, Break: 1.5A Max.
VA: Make: 3,600V A, Break: 360V A |
D4C (with indicator) |
B150 (Carry current: 5 A):
120 V AC: Make: 30 A, Break: 3.0 A
Max. VA: Make: 3,600 VA, Break: 360 VA |
D4CC |
D150 (Carry
current: 1 A):
120 V AC: Make: 3.6 A, Break: 0.6 A
Max. VA: Make: 432 VA, Break: 72 VA
1 A 30 VDC |
SHL-[]55 |
A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A Max.
VA: Make: 7,200VA, Break: 720VA |
D4MC
ZC |
A300(Carry current:
10A):1/2A 125V 1/4A 250V DC Resistive 120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A Max. VA: Make: 7,200VA, Break: 720VA |
ZC-01
D4MC-C |
0.1A, 125V AC (resistive
load) 0.1A, 30V DC |
ZE/ZV/ZV2 |
15A, 125, 250 or 480V AC
0.5A 125V DC, 0.25A 250V DC
1/8HP 125V AC, 1/4HP 250V AC |
D4E-N |
A300 (Carry current: 10 A):
120 V AC: Make: 60 A, Break: 6.0 A
240 V AC: Make: 30 A, Break: 3.0 A
Max. VA: Make: 7,200 VA, Break: 720 VA |
Note:
Certification is sometimes obtained with
representative models. Ask your OMRON representative for details on the
standards. The applicable standard number is given in the "Standard No." column.
The certification report number is given in the "File No." column.
Push
Buttons / Indicator Lamps
|
Model |
Ratings |
Standard No. |
File No. |
Remarks |
|
A16 |
5A 125V AC (General Use) 3A 250V AC (General Use) 3A 30V DC (Resistive) |
UL508 |
E41515 |
Certified for the Socket. |
|
A22 |
6A 220V AC (General Use) 10A 110V AC (General Use) |
Certified for the Switch
Block and Lamp Socket. |
|
A3A[]-9[]K A3A[]-9[]L |
6A 125V AC, 2A 250V AC (General Use) 4A 30V DC (Resistive) |
- |
A3A[]-9[]A A3A[]-9[]B |
3A 125V AC (General Use) 2A 30V DC (Resistive) |
A3C |
1A 125V AC, 0.5A 250V AC (General Use) 1A 30V DC (Resistive) 0.1A 125V AC (General Use) 0.1A 30V DC (Resistive) |
Certified for the Switch. |
A3K |
3A 250V, 5A 125V
AC (General Use)
3A 30V DC (Resistive)
0.1A 125V AC (General Use)
0.1A 30V DC (Resistive) |
A3P |
5A 125V AC, 3A 250V AC (General Use) 0.1A 125V AC (General Use) 0.1A 30V DC (Resistive) |
A3S |
2A 250V AC, 3A 125V AC (General Use) 0.1A 125V AC (General Use) 0.1A 30V DC (Resistive) |
M2C |
Lamp 28V 1W max. |
Certified for the main
unit. |
M2K |
Lamp 24V DC 1W |
M2P |
Lamp 28V 1.2W max. |
M2S |
Lamp 28V 1.2W max. |
M16 |
Lamp 24V max. (Input Voltage) 120V AC (Input Voltage) with Voltage Reduction Unit 240V AC (Input Voltage) with Voltage Reduction Unit |
Certified for the Socket. |
M22 |
Lamp 120V 2.6W max. (Input Voltage) 110V AC (Input Voltage) with Voltage Reduction Unit 220V AC (Input Voltage) with Voltage Reduction Unit |
Certified for the Lamp
Socket. |
General-purpose Relays
|
Model |
Number of Poles |
Operating Coil Ratings |
Contact Ratings |
File No. |
|
MY( ) ("New" model) |
2 |
6 to 240V AC 5 to 125V DC |
10A 30V DC
(General Use) 10A 250V AC (General Use) |
E41515
(UL508) |
4 |
5A 250V AC (General Use)
5A 30V DC (General Use) |
MY( ) (excluding "New" model) |
2 |
6 to 240V AC 6 to 125V DC |
5A 28V DC (Resistive) 5A 240V AC (General Use) |
3 |
4 |
5A 240V AC (General Use) (Same polarity) 5A 28V DC (Resistive) (Same polarity) |
LY( ) |
1 |
6 to 240V AC 6 to 125V DC |
15A 30V DC (Resistive) 10A 240V AC (Resistive) TV-5 120V AC TV rating 1/2HP 120V AC power rating |
E41643
(UL508) |
2 |
15A 120V AC (Resistive) 15A 30V AC (Resistive) 10A 240V AC (General Use) 1/2HP 120V AC power rating TV-3 120V AC TV rating |
3 |
10A 30V DC (Resistive) 10A 240V AC (General Use) 1/2HP 120V AC power rating |
4 |
|
G2R-( )-S |
1 |
3 to 240V AC
3 to 110V DC |
10A 30V DC
(Resistive)
10A 250V AC (General Use)
TV-3 (N. O. only) |
E41463
(UL508) |
|
2 |
5A 30V DC (Resistive)
5A 250V AC (General Use)
TV-3 (N. O. only) |
MK |
2 3 |
6 to 260V AC 6 to 130V DC |
Ag contacts 5A 230V AC (Resistive) 5A 28V DC (Resistive) |
E41515
(UL508) |
AgCdO contacts 10A 230V AC (Resistive) 10A 28V DC (Resistive) |
|
MK-S |
2
3 |
6 to 240V AC
6 to 125V DC |
10A 250V AC (Resistive)
10A 28V DC (Resistive)
7A 250V AC (General Use) |
|
MK-S(X) |
1
2 |
24 to 240V AC
12 to 220V DC |
MKS1XT: 10A 220V
DC (Resistive, NO)
MKS2XT: 5A 220V DC (Resistive, NO); 2A 220V DC (Resistive, NC)
MKS1T: 15A 250V AC (Resistive, NO)
MKS2T: 15A 250V AC (Resistive, NO); 5A 250V AC (Resistive, NC) |
E76675
(UL508) |
G7J-( )-P(Z) G7J-( )-B(Z) G7J-( )-T(Z) |
4PST-NO 3PST-NO/ SPST-NC DPST-NO/ DPST-NC |
24 to 240V AC 6 to 110V DC |
NO contact
(Single Contact)
25A 277V AC (Resistive)
25A 120V AC (General Use)
25A 277V AC (General Use)
1.5kW 120V AC (Tungsten)
1.5HP 120V AC
3HP 240/265/277V AC
3-phasa 3HP 240/265/277V AC
3-phasa 5HP 240/265/277V AC
20FLA/120LRA 120V AC
17FLA/102LRA 277V AC
TV-10 120V AC
25A 30V DC (Resistive) |
E41463
(UL508) |
NC contact
(Single Contact)
8A 277V AC (Resistive)
8A 120V AC (General Use)
8A 277V AC (General Use)
8A 30V DC (Resistive) |
NO contact (Twin Contacts) 1A 277V AC (General Use) |
NC contact (Twin Contacts) 1A 277V AC (General Use) |
|
G7Z |
4 |
12, 24V DC |
NO contact:
40A 480V AC (Resistive)
5A 120V DC (Resistive)
22A 480V AC (General Use)
NC contact:
25A 480V AC (Resistive)
5A 120V DC (Resistive)
10A 480V AC (General Use) |
E41643
(UL508) |
G7T-1122S |
SPST-NO |
12 to 125V DC 24 to 240V DC |
1A 125V AC
(Resistive)
1A 125V DC (Resistive)
5A 30V DC (Resistive)
1A 250V AC (General Purpose) |
E41463
(UL508) |
G7T-1112S |
SPST-NO |
5A 125V AC (Resistive)
5A 250V AC (General Use)
10A 250V AC (General Use)
10A 30V DC (Resistive)
1/2HP 240V AC |
Solid-state
Relays
Note:
Applicable standard numbers are given in parentheses in the File No. column.
Switching Power Supplies
|
Model |
Ratings |
Standard No. |
File No. |
Marking |
Listed/
Recognized |
Category |
S82S |
12 to 24V DC |
UL508 |
E104818 |
RU |
Recognized |
NMTR2 |
|
S82W |
100/110/120V AC |
UL1012 |
E105544 |
RU |
Recognized |
QQFU2 |
|
S8AS |
100 to 240V AC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8JX-G (15, 30, 50, 100, 150W) |
100 to 240V AC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL60950 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8JX-G (300, 600W) |
100 to 120V AC /
200 to 240V AC |
UL508 |
E316988 |
cRUus |
Listed |
NMTR2/NMTR8 |
|
UL60950 |
E319923 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8M |
24V DC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8T-DCBU-01 |
24V DC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL1604 |
E198998 |
cULus |
Listed |
NRAG/NRAG7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8T-DCBU-02 |
24V DC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL1604 |
E198998 |
cULus |
Listed |
NRAG/NRAG7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8TS
(25/30/60W) |
100 to 240V AC |
UL1604 |
E198998 |
cULus |
Listed |
NRAG/NRAG7 |
|
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8VM (15/30/50/100/
150/300(24V)/
600W(24V)) |
100 to 240V AC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL1604 |
E198998 |
cULus |
Listed |
NRAG/NRAG7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8VM (300(5/12/15V)/
600(5/12/15V)/
1500W) |
100 to 240V AC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
S8VS (15, 30W) |
100 to 240V AC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
UL1604 |
E198998 |
cULus |
Listed |
NRAG/NRAG7 |
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
|
S8VS (60, 90, 120, 180, 240, 480W)
Screw terminal block |
100 to 240V AC |
UL508 |
E104818 |
cULus |
Listed |
NMTR/NMTR7 |
|
UL60950-1 |
E152784 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
S8VS (60, 90, 120, 180, 240, 480W)
Screwless terminal block |
100 to 240V AC |
UL508 |
E316988 |
cULus |
Listed |
NMTR/NMTR7 |
UL60950-1 |
E319923 |
cRUus |
Recognized |
QQGQ2/QQGQ8 |
Supplying Power to Sensors with DC Power Supplies.
If a class-2 power supply is used, the Sensor
itself does not have to be UL compliant; a standard model may be used. The
following Power Supplies comply with class 2.
* Refer to the ratings, characteristics, and
functions of the S8T-DCBU-01 and S8T-DCBU-02 for details.
Note: Products that are certified for UL 1604 can
be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.
Description of Hazardous Locations:
[Class]
Class I: Locations in which flammable gases or vapors may be present in the air
in sufficient quantities to be explosive or ignitable.
Class II: Locations in which there is combustible dust.
Class III: Locations in which easily ignitable fibers or flyings are present but
are not airborne in sufficient quantities to ignite.
[Division]
Division 1: Locations in which explosive or ignitable material is normally
present or is present at certain times.
Division 2: Locations in which explosive or ignitable material is not normally
present (but may accidentally exist).
[Group]
Class I:
Group A: Acetylene
Group B: Combustible gas/vapor, example: hydrogen
Group C: Combustible gas/vapor, example: ethylene
Group D: Combustible gas/vapor, example: propane
Axial Fans
Power/Protective Components and Power Sensors
|
Model |
Ratings |
File No. |
|
SDV-F[][]
|
24V DC, 48V DC,
100/110V DC, 125V DC,
100/110V AC, 200/220V AC |
E41515 |
|
K8AB-AS/-VS/-VW
|
24V AC/DC,
100/115V AC, 200/230V AC |
E76675 |
|
K8AB-PH
|
200-500V AC
(3-phase three-wire system) |
|
K8AB-PA/PM/PW
|
200-480V AC (3-phase
three-wire system) |
|
K8AC-H
|
100-240V AC |
E200593 |
Terminal Relays
|
Model |
Number of Poles |
Operating Coil Ratings |
Contact Ratings |
File No. |
|
G6B-4( )
|
4 |
3 to 24V DC |
5A 250V AC
(General Use)
5A 30V DC (Resistive)
1/6HP 250V AC
1/8HP 250V AC
360WT 120V AC (Tungsten)
250VA 125V AC (Pilot Duty)
250VA 250V AC (Pilot Duty)
26.4VA 30V DC (Pilot Duty)
530VA 20 to 265V AC (Pilot Duty)
TV-2 120V AC TV rating |
E87929
(UL508) |
|
G6B-47( )
|
8A 250V AC
(General Use)
8A 30V DC (Resistive)
1/6HP 250V AC
1/8HP 250V AC
360WT 120V AC (Tungsten)
250VA 125V AC (Pilot Duty)
26.4VA 30V DC (Pilot Duty)
530VA 20 to 265V AC (Pilot Duty)
TV-2 120V AC TV rating |
|
G6D-F4B
|
4PST-NO |
12, 24V DC |
5A 250V AC
5A 30V DC |
|
G6DZ-F4B
|
0.3A 3 to 264V AC
0.3A 3 to 125V DC |
Common
Accessories
|
Model |
Contact Ratings |
File No. |
|
PF083A PF113A |
10A 250V |
E87929 |
8PFA 8PFA1 11PFA 14PFA |
7.5A 250V |
PY[] PYF[]A PYF[]A-E |
7A 250V |
|
PYF08S |
10A 250V AC |
|
PYF14S |
10A 250V AC |
PT08 PT08A(-E) |
15A 250V |
PT11 PT14 PT11A PT14A(-E) |
10A 250V |
P2CF-08(-E) P2CF-11(-E) |
10A, 250V AC |
P3G-08 |
6A, 250V AC |
P3GA-11 |
6A, 250V AC |
PL08 PL11
PLE08-0
PLE11-0 |
10A 260V AC |
P6B-06 |
8A 250V AC |
P6B-26P |
5A 250V AC |
P6C |
10A 250V AC |
P2R(F)-05(-E) |
10A 300V AC |
P2R(F)-08(-E) |
5A 300V AC |
P2RF-05-S |
10A 250V AC |
P2RF-08-S |
5A 250V AC |
P6D |
-- |
UL Certification on Other
Product Categories
|