LR Standards (UK Marine Standards)
Programmable Controllers
|
Model |
Environmental Category |
|
ENV1 |
ENV2 |
ENV3 |
ENV4 |
ENV5 |
Remarks |
|
C200HW/C200HX/C200HG/C200HE/C200HS |
|
|
|
|
|
* |
|
CJ1/CJ2 |
|
|
|
|
CP1 |
|
|
|
|
CPM1A /
CPM2A |
|
|
|
|
CPM2C |
|
|
|
|
CQM1H / CQM1 |
|
|
|
|
CS1 |
|
|
|
CV500/CV1000/CV2000/CVM1/CVM1D/
C500/3G2A9/C1000 |
|
|
|
*
General Power distribution Zones
Note:
1. The
above table lists series names. Ask your OMRON representative for details on
specific model numbers.
2. Model certification has not been received for usage on the deck, in the
bridge, or in locations subject to strong vibration.
Model certification for the LR (Lloyd's Register of Shipping) was made according
to the LR Type Approval System Test Specification No. 1.
Field
Networks
* General Power distribution Zones
Note:
1. The above table lists series names. Ask your
OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the
bridge, or in locations subject to strong vibration.
Programmable
Terminals
*1.
General Power distribution Zones
*2. "Bridge & Deck Zone" and "General Power Distribution Zones "
Note:
1. The
above table lists series names. Ask your OMRON representative for details on
specific model numbers.
2. NS-series PTs are certified for the bridge.
When using an NS-series PT on the bridge, attach a noise
filter and an electromagnetic shield.
Use the TAH-06-683 from Cosel Co., Ltd., for the noise filter.
Use the E09F-100 or E09R13502P from Seiwa Electric Mfg. Co., Ltd., for the
electromagnetic shield.
Refer to the product manuals for details.
3. Model certification has not been received for usage on the deck, in the
bridge (except for NS-series PTs), or in locations subject to strong vibration.
Timers
|
Model |
Ratings |
Environmental Category |
|
ENV1 |
ENV2 |
ENV3 |
ENV4 |
ENV5 |
Remarks |
|
H3CA-A H3CA-FA |
24 to 240V AC, 12 to 240V DC |
|
|
|
|
|
* |
H3CA-8 H3CA-8H |
24 to 240V AC, 12 to 110V DC |
|
H3CR-A H3CR-A8 H3CR-AP |
100 to 240V AC/100 to 125V DC, 24 to 48V AC/12 to 48V DC |
|
H3CR-A8E |
100 to 240V AC/100 to 125V DC, 24 to 48V AC/DC |
|
H3CR-AS H3CR-A8S |
24 to 48V AC/12 to 48V DC |
|
H3CR-F H3CR-F8 H3CR-FN H3CR-F8N |
100 to 240V AC, 24V AC/DC 12, 48 to 125V DC |
|
H3CR-G8L H3CR-G8EL |
100/110/120, 200/220/240V AC |
|
H3CR-HRL H3CR-H8L H3CR-H8RL |
100 to 120V AC 200 to 240V AC 24V AC/DC, 48V DC 100 to 125V DC |
|
H3DK |
12V DC, 24 to 48V AC/DC, 24
to 240V AC/DC, 100 to 120V AC, 200 to 240V AC |
|
H3DS-AL H3DS-ALC H3DS-ML H3DS-MLC H3DS-SL H3DS-SLC |
24 to 230V AC/24 to 48V DC |
H3M, H3M-H |
24 to 240V AC, 12 to 110V DC |
H3Y-2, H3Y-4 |
24 to 230V AC, 12 to 110V DC |
H3YN-2 H3YN-21 H3YN-4 H3YN-41 |
24, 100 to 120, 200 to 230V AC 12, 24, 48, 100 to 110, 125V DC |
*
General Power Distribution Zones
Note:
1. The
above table lists series names. Ask your OMRON representative for details on
specific model numbers.
2. Model certification has not been received for usage on the deck, in the
bridge, or in locations subject to strong vibration.
Model
certification for the LR was made according to the LR Type Approval System Test
Specification No. 1. Refer to the following table for environmental categories.
|
ENV1 |
Controlled environments
only, to producer's specification |
|
ENV2 |
Enclosed spaces subject to
temperature, humidity and vibration: 5 to 55ēC |
|
ENV3 |
Enclosed spaces subject to
generated heat from other equipment: 5 to 70ēC |
|
ENV4 |
Mounted on reciprocating
machinery: 5 to 55ēC |
|
ENV5 |
Open decks: -25 to 70ēC |
Note:
Models that are certified for an ENV2 environment can also be used in an ENV1
environment.
Counters
* General Power Distribution Zones
Note:
1. The above table lists series names. Ask your
OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the
bridge, or in locations subject to strong vibration.
Model certification for the LR was made according
to the LR Type Approval System Test Specification No. 1. Refer to the following
table for environmental categories.
|
ENV1 |
Controlled
environments only, to producer's specification |
|
ENV2 |
Enclosed spaces
subject to temperature, humidity and vibration: 5 to 55ēC |
|
ENV3 |
Enclosed spaces
subject to generated heat from other equipment: 5 to 70ēC |
|
ENV4 |
Mounted on
reciprocating machinery: 5 to 55ēC |
|
ENV5 |
Open decks: -25
to 70ēC |
Note: Models that are certified for an ENV2
environment can also be used in an ENV1 environment.
General-purpose Relays
|
Model |
Number of Poles |
Operating Coil Ratings |
Contact Ratings |
Certification No. |
|
MY( ) ("New" model) |
2 |
6 to 240V AC 6 to 125V DC |
10A 250V AC (Resistive) 2A 250V AC (PF0.4) 10A 30V DC (Resistive) 2A 30V DC (L/R=7ms) |
98/10014 |
4 |
5A 250V AC (Resistive) 0.8A 250V AC
(PF0.4) 5A 30V DC (Resistive) 1.5A 30V DC (L/R=7ms) |
MY( ) (excluding "New" models) |
2 |
6 to 240V AC 6 to 120V DC |
2A 30V DC (L/R=7ms) 2A 200V AC
(cosφ=0.4) |
90/10270 |
4 |
1.5A 30V DC (L/R=7ms) 0.8A 200V AC
(cosφ=0.4) 1.5A 115V AC (cosφ=0.4) |
LY( ) |
2 |
6 to 240V AC 6 to 110V DC |
7.5A 230V AC (cosφ=0.4) 5A 24V DC
(L/R=7ms) |
90/10269 |
4 |
MK2(P) |
2 |
6 to 240V AC 6 to 200V DC |
7.5(5)A 220V AC (Resistive Load) 5(3)A 24V DC
(Resistive Load) 3(2)A 220V AC (Inductive Load) 4(2.5)A 24V DC (Inductive Load) |
91/10221 |
MK3(P) |
3 |
5(3)A 220V AC (Resistive Load) 3(2)A 24V DC
(Resistive Load) 2(1.2)A 220V AC (Inductive Load) 2.5(1.5)A 24V DC (Inductive Load) |
MK[]ZP |
2 3 |
3A 220V AC (Resistive Load) 2A 24V DC
(Resistive Load) 1.2A 220V AC (Inductive Load) 1.5A 24V DC (Inductive Load) |
MM[](B) |
2 3 4 |
6 to 240V AC 6 to 220V DC |
15A 220V AC (General Use) 10A 24V DC
(General Use) |
91/10219 |
MM[]X(B) |
10A 110V DC (Resistive Load) 7A 110V DC
(Inductive Load) |
MM[]P |
7.5A 220V AC (General Use) 5A 24V DC
(General Use) |
MM[]XP |
7A 110V DC (Resistive Load) 6A 110V DC
(Inductive Load) |
MM[]K(B) |
2 3 4 |
6 to 200V AC 6 to 220V DC |
10A 220V AC (General Use) 7A 24V DC
(General Use) |
91/10220 |
MM[]XK(B) |
7A 110V DC (Resistive Load) 6A 110V DC
(Inductive Load) |
MM[]KP |
5A 220V AC (General Use) 4A 24V DC
(General Use) |
MM[]XKP |
5A 110V DC (General Use) |
MYA (excluding models ending in "-LA12" or "-LB12")) |
- |
6 to 240V AC 6 to 125V DC |
220V AC 3A (cosφ=1) 220V AC 0.8A (cosφ=0.4) 24V DC 3A (L/R=0ms) 24V DC 1.5A (L/R=7ms) |
90/10035 |
G2R |
1 2 |
3 to 240V AC 3 to 110V DC |
* |
94/10019 |
*Ask your OMRON representative for settings.
Reduce
Wiring Devices
|
Model |
Environmental
Category |
|
ENV1 |
ENV2 |
ENV3 |
ENV4 |
ENV5 |
Remarks |
|
G71/G72C/G730 |
|
|
|
|
|
General power
distribution zones |
Power/Protective Components and Power Sensors
|
Model |
Ratings |
Certification No. |
|
K2WR-R |
AC 5A,
100/110/200/220V AC 50/60Hz |
90/10178(E4) |
Temperature Controllers
|
Model |
Ratings |
Environmental
Category |
|
ENV1 |
ENV2 |
ENV3 |
ENV4 |
ENV5 |
Remarks |
|
E5AN |
24VAC/DC
100-240VAC |
|
|
|
|
|
General power
distribution zones |
|
E5EN |
|
E5CN |
Note:
1. The above table lists series names. Ask your
OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the
bridge, or in locations subject to strong vibration.
Model certification for the LR was made according
to the LR Type Approval System Test Specification No. 1. Refer to the following
table for environmental categories.
|
ENV1 |
Controlled
environments only, to producer's specification |
|
ENV2 |
Enclosed spaces
subject to temperature, humidity and vibration: 5 to 55ēC |
|
ENV3 |
Enclosed spaces
subject to generated heat from other equipment: 5 to 70ēC |
|
ENV4 |
Mounted on
reciprocating machinery: 5 to 55ēC |
|
ENV5 |
Open decks: -25
to 70ēC |
Note: Models that are certified for an ENV2