D5V

Contact Displacement Sensor

D5V

Contact Displacement Sensor with Built-in Amplifier That Enables In-line Measurement of a Wide Range of Objects with a Low Operating Force

Approved Standards

Approved Standard Ratings

Conformance to EN50081-1, pr50082-2

Rated current 100 mA
Rated voltage 24 VDC

Model D5VA-3[]1 D5VM-3[]1
Supply voltage 12 to 24 VDC±10% (See note 1.)
Current consumption 80 mA max.
Measurement range 5 mm
Maximum actuator travel
distance
Approx. 5.7 mm
Offset adjustment range ±0.25 mm
Resolution 10 μm 1μm
Linearity 0.5% FS max.
Repeat accuracy 10 μm max.
Response time 6 ms max. 37 ms max. (including transmission delay time)
Operating force 0.3 N max.
Output Linear current output: 4 to 20 mA
(Allowable load resistance: 0 to 300 Ω)
B7A serial communications output (See note 2.)
(BCD and multipoint ON/OFF output modes) (See note 3.)
Mounting method Two M4 screws
Indicators Power and overtravel indicators Power, overtravel, setting, and output indicators
Mechanical durability 10,000,000 operations min.
Temperature influence ±0.04% FS/°C max.
Operating temperature -10 to 55 °C (with no icing or condensation)
Storage temperature -25 to 65 °C (with no icing or condensation)
Humidity range 35% to 85% (with no icing or condensation)
Insulation resistance 100 MΩ min. (at 100 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Noise resistance 1.5 kV with a pulse width of 100 ns to 1 μs
Vibration resistance 10 to 55 Hz, 0.75-mm double amplitude
Shock resistance 196 m/s2
Connection cable 2 m (XS3F-M421-402-R provided)
Weight Approx. 80 g (without cable)
Material ABS and PC polymer alloy

Note:
1. If power is supplied to both the D5VM-3[]1 and B7A Output Link Terminal from a single power supply, the supply voltage must be 24 VDC±10%.
2. Connectable models:

Model number Description
B7A-R6[][]1
B7AS-R6B[]1
Screw-terminal models
B7A-R[]A[]3-[] PC-connector models
C200H-B7A21
C200H-B7A22
C200H-B7A11
C200H-B7A12
C200H B7A Interface Units
CQM1-B7A21
CQM1-B7A12
CQM1-B7A13
CQM1 B7A Interface Units
CJ1W-B7A22
CJ1W-B7A14
CJ1W-B7A04
CJW1 B7A Interface Units
for use in standard mode only)

3. BCD or multipoint output mode can be selected with the mode selector.