Photoelectric Sensor with Separate Digital Amplifier (Laser-type)
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: September 2, 2015
Item | Diffuse-reflective | Coaxial Retro-reflective (with M.S.R. function) | |||||
---|---|---|---|---|---|---|---|
E3C-LD11 | E3C-LD21 | E3C-LD31 | E3C-LR11 | E3C-LR11
+ E39-P31 |
E3C-LR11
+ E39-P41 |
E3C-LR12 | |
Light source
(wavelength) |
Red semiconductor laser diode (650
nm), 3 mW max. (JIS Class 2, IEC/EN Class 2, and FDA Class 2) |
Red semiconductor laser diode (650
nm), 3 mW max. (JIS Class 2, IEC/EN Class 2, and FDA Class 2) |
1 mW max.
(JIS Class 1, IEC/EN Class 1, and FDA Class 2) |
||||
Sensing
distance |
High-resolution mode: 30 to 1,000 mm
Standard mode: 30 to 700 mm Super-high-speed mode: 30 to 250 mm *1 |
7 m
5 m 2 m *2 |
1,700 mm
1,300 mm 700 mm *2 |
900 mm
700 mm 400 mm *2 |
7 m
5 m 2 m *2 |
||
Focus *3 | 0.8 mm max.
(at distances up to 300 mm) |
33 mm
(at 150 mm) |
33 × 15 mm
(at 150 mm) |
0.8 mm max.
(at distances up to 1,000 mm) |
28 mm
(at 150 mm) |
28 × 16 mm
(at 150 mm) |
2.0-mm dia.
(at distance up to 1,000 mm) |
Functions | Variable focal point mechanism (focus adjustment) *4, optical axis adjustment mechanism (axis
adjustment) |
||||||
Indicators | LDON indicator: Green; Operation indicator: Orange | ||||||
Ambient
illumination (Receiver side) |
Incandescent lamp: 3,000 lx | ||||||
Ambient
temperature |
Operating: -10 to 55°C, Storage: -25 to 70°C (with no icing or condensation) | ||||||
Ambient
humidity |
Operating/storage: 35% to 85% (with no condensation) | ||||||
Insulation
resistance |
20 MΩ min. at 500 VDC | ||||||
Dielectric
strength |
1,000 VAC at 50/60 Hz for 1 minute | ||||||
Shock
resistance |
Destruction: 300 m/s2 6 directions 3 times each (up/down, right/left, forward/backward) | ||||||
Vibration
resistance |
Destruction: 10 to 150 Hz with double amplitude of 0.7 mm, in X, Y, and Z directions for 80 min each | ||||||
Degree of
protection |
IP40 (IEC) | IP40 (IEC 60529) | |||||
Connection
method |
Connector (standard cable length: 2 m) | ||||||
Materials | Case and cover: ABS
Front surface filter: Methacrylic resin |
Case and cover: ABS
Front surface filter: Glass |
|||||
Weight
(packed state) |
Approx. 85 g | Approx. 100 g | |||||
Accessories | Instruction manual, Laser warning labels (English) |
Type | External-input
models |
Twin-output models | ATC-output
models |
Analog-output
models |
|||||
---|---|---|---|---|---|---|---|---|---|
Standard models | Standard models | Model for
Sensor Commu- nications Unit |
Standard models | Standard models | |||||
Pre-
wired |
Wire-
saving con- nector |
Pre-
wired |
Wire-
saving con- nector |
Pre-
wired |
Wire-
saving con- nector |
Pre-wired | |||
Model | NPN
output |
E3C-
LDA21 |
E3C-
LDA7 |
E3C-
LDA11 |
E3C-
LDA6 |
E3C-
LDA0 *1 |
E3C-
LDA11AT |
E3C-
LDA6AT |
E3C-LDA11AN |
PNP
output |
E3C-
LDA51 |
E3C-
LDA9 |
E3C-
LDA41 |
E3C-
LDA8 |
E3C-
LDA41AT |
E3C-
LDA8AT |
E3C-LDA41AN | ||
Supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% max. | ||||||||
Power consumption | 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) | ||||||||
Control
output |
ON/OFF
output |
Load power supply voltage: 26.4 VDC max.; NPN/PNP (depends on model) open collector
Load current: 50 mA max.; residual voltage: 1 V max. |
|||||||
Analog
output |
--- | Control output
Voltage output: 1 to 5 VDC (connected load 10 kΩ min.) Temperature characteristics 0.3% F.S./°C Response time/ Repeat accuracy Super-high-speed mode: 100 μs/4.0% F.S. High-speed mode: 250 μs/4.0% F.S. Standard mode: 1 ms/2.0% F.S. High-resolution mode: 4 ms/ 2.0% F.S. |
|||||||
Re-
sponse time |
Super-high-
speed mode *2 |
80 μs for
operation and reset |
100 μs for
operation and reset |
--- | 100 μs for operation and reset | ||||
High-speed
mode |
250 μs for operation and reset | ||||||||
Standard
mode |
1 ms for operation and reset | ||||||||
High-
resolution mode |
4 ms for operation and reset | ||||||||
Func-
tions |
Differential
detection |
Switchable between single edge and double edge detection mode.
Single edge: Can be set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms. Double edge: Can be set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms. |
--- | ||||||
Timer
function |
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1-s increments) |
||||||||
Zero-reset | Negative values can be displayed. | ||||||||
Initial reset | Settings can be returned to defaults as required. | ||||||||
Mutual
interference prevention |
Possible for up to 10 Units. *2 | ||||||||
Counter | Switchable
between up counter and down counter. Set count: 0 to 9,999,999 |
--- | |||||||
I/O settings | External input
setting (Select from teaching, power tuning, zero reset, light OFF, or counter reset.) |
Output setting (Select from
channel 2 output, area output, or self-diagnosis.) |
Output setting (Select
from channel 2 output, area output, self-diagnosis, or ATC error output.) |
Analog output
setting (Offset voltage can be adjusted.) |
|||||
Digital display | Select from digital incident level + threshold or six other patterns. | ||||||||
Display orientation | Switching between normal/reversed display is possible. | ||||||||
Ambient temperature
range *3 |
Operating: Groups of 1 to 2 Amplifiers: -25°C to 55°C, Groups of 3 to 10 Amplifiers: -25°C to
50°C, Groups of 11 to 16 Amplifiers: -25°C to 45°C Storage: -30°C to 70°C (with no icing) |
||||||||
Ambient humidity
range |
Operating and storage: 35% to 85% (with no condensation) | ||||||||
Insulation resistance | 20 MΩ at 500 VDC | ||||||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. | ||||||||
Vibration resistance
*4 |
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||||||
Shock resistance *5 | Destruction: 500 m/s2, 3 times each in X, Y, and Z directions | ||||||||
Degree of protection | IP50 (IEC 60529) | ||||||||
Connection method | Pre-wired or wire-saving connector *6 | ||||||||
Weight (packed state) | Pre-wired Models: Approx. 100 g
Wire-saving Connector Models: Approx. 55 g Sensor Communications Unit Connector Models: Approx. 55 g |
||||||||
Materi-
als |
Case | Polybutylene terephthalate (PBT) | |||||||
Cover | Polycarbonate |