Measuring and Monitoring Relays
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: October 11, 2012
Single-phase Current Relay | Measuring current | Supply voltage | Model |
---|---|---|---|
![]() |
2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC |
24 VAC/DC | K8AB-AS1 24 VAC/DC |
100-115 VAC | K8AB-AS1 100-115 VAC | ||
200-230 VAC | K8AB-AS1 200-230 VAC | ||
0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC |
24 VAC/DC | K8AB-AS2 24 VAC/DC | |
100-115 VAC | K8AB-AS2 100-115 VAC | ||
200-230 VAC | K8AB-AS2 200-230 VAC | ||
10 to 100 A AC, 20 to 200 A AC (See note.) |
24 VAC/DC | K8AB-AS3 24 VAC/DC | |
100-115 VAC | K8AB-AS3 100-115 VAC | ||
200-230 VAC | K8AB-AS3 200-230 VAC |
Current Transformer | Input range | Applicable Relay | Model |
---|---|---|---|
![]() |
10 to 100 A AC, 20 to 200 A AC |
K8AB-AS3 | K8AC-CT200L |
CT current on secondary side | Applicable Relay |
---|---|
0 to 1 A AC, 0 to 5 A AC |
K8AB-AS2 |
Single-phase Voltage Relay | Measuring voltage | Supply voltage | Model |
---|---|---|---|
![]() |
6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC |
24 VAC/DC | K8AB-VS1 24 VAC/DC |
100-115 VAC | K8AB-VS1 100-115 VAC | ||
200-230 VAC | K8AB-VS1 200-230 VAC | ||
1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC |
24 VAC/DC | K8AB-VS2 24 VAC/DC | |
100-115 VAC | K8AB-VS2 100-115 VAC | ||
200-230 VAC | K8AB-VS2 200-230 VAC | ||
20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC |
24 VAC/DC | K8AB-VS3 24 VAC/DC | |
100-115 VAC | K8AB-VS3 100-115 VAC | ||
200-230 VAC | K8AB-VS3 200-230 VAC |
A shunt is a resistor to convert a DC current into a DC voltage.
Use the shunt in combination with K8AB-VS to detect undercurrent and overcurrent in DC circuits.
Model | Rated current | Output voltage |
---|---|---|
SDV-SH5 | 5 A | 60 mV |
SDV-SH7.5 | 7.5 A | |
7.5 A (for 100 mV) | 100 mV | |
SDV-SH10 | 10 A | 60 mV |
SDV-SH15 | 15 A | |
SDV-SH20 | 20 A | |
SDV-SH30 | 30 A | |
SDV-SH50 | 50 A | |
SDV-SH75 | 75 A | |
SDV-SH100 | 100 A | |
SDV-SH150 | 150 A | |
SDV-SH200 | 200 A | |
SDV-SH300 | 300 A | |
SDV-SH500 | 500 A | |
SDV-SH750 | 750 A | |
SDV-SH1000 | 1,000 A |
Single-phase Voltage Relay | Measuring voltage | Supply voltage | Model |
---|---|---|---|
![]() |
6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC |
24 VAC/DC | K8AB-VW1 24 VAC/DC |
100-115 VAC | K8AB-VW1 100-115 VAC | ||
200-230 VAC | K8AB-VW1 200-230 VAC | ||
1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC |
24 VAC/DC | K8AB-VW2 24 VAC/DC | |
100-115 VAC | K8AB-VW2 100-115 VAC | ||
200-230 VAC | K8AB-VW2 200-230 VAC | ||
20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC |
24 VAC/DC | K8AB-VW3 24 VAC/DC | |
100-115 VAC | K8AB-VW3 100-115 VAC | ||
200-230 VAC | K8AB-VW3 200-230 VAC |
A shunt is a resistor to convert a DC current into a DC voltage.
Use the shunt in combination with K8AB-VW to detect undercurrent and overcurrent in DC circuits.
Model | Rated current | Output voltage |
---|---|---|
SDV-SH5 | 5 A | 60 mV |
SDV-SH7.5 | 7.5 A | |
7.5 A (for 100 mV) | 100 mV | |
SDV-SH10 | 10 A | 60 mV |
SDV-SH15 | 15 A | |
SDV-SH20 | 20 A | |
SDV-SH30 | 30 A | |
SDV-SH50 | 50 A | |
SDV-SH75 | 75 A | |
SDV-SH100 | 100 A | |
SDV-SH150 | 150 A | |
SDV-SH200 | 200 A | |
SDV-SH300 | 300 A | |
SDV-SH500 | 500 A | |
SDV-SH750 | 750 A | |
SDV-SH1000 | 1,000 A |
Phase-sequence Phase-loss Relay | Functions | Rated input voltage * | Model |
---|---|---|---|
![]() |
Phase sequence and
phase loss monitoring |
200 to 500 VAC | K8AB-PH1 |
* The power supply is shared with the rated input voltage.
Three-phase Phase-sequence Phase-loss Relay | Rated input (See note 2.) | Model | |
---|---|---|---|
![]() |
3-phase 3-wire mode | 200, 220, 230, 240 VAC | K8AB-PM1 |
3-phase 4-wire mode | 115, 127, 133, 138 VAC | ||
3-phase 3-wire mode | 380, 400, 415, 480 VAC | K8AB-PM2 | |
3-phase 4-wire mode | 220, 230, 240, 277 VAC |
Three-phase Asymmetry and Phase-sequence Phase-loss Relay |
Rated input (See note 2.) | Model | |
---|---|---|---|
![]() |
3-phase 3-wire mode | AC 200, 220, 230, 240 | K8AB-PA1 |
3-phase 4-wire mode | AC 115, 127, 133, 138 | ||
3-phase 3-wire mode | AC 380, 400, 415, 480 | K8AB-PA2 | |
3-phase 4-wire mode | AC 220, 230, 240, 277 |
Three-phase Voltage Relay | Rated input (See note 2.) | Model | |
---|---|---|---|
![]() |
3-phase 3-wire mode | 200, 220, 230, 240 VAC | K8AB-PW1 |
3-phase 4-wire mode | 115, 127, 133, 138 VAC | ||
3-phase 3-wire mode | 380, 400, 415, 480 VAC | K8AB-PW2 | |
3-phase 4-wire mode | 220, 230, 240, 277 VAC |
Size | Supply
voltage |
Type | Number of
outputs |
Input type | Setting unit
(setting range) |
Model |
---|---|---|---|---|---|---|
K8AB-TH
22.5 × 90 × 100 mm |
100 to
240 VAC |
Temper-
ature input |
1 (relay) | Thermocouple/Pt100 | Unit: 1°C/°F (0 to 399°C/°F) | K8AB-TH11S |
Thermocouple | Unit: 10°C/°F (See note 1.) | K8AB-TH12S | ||||
24 VAC/
VDC |
Thermocouple/Pt100 | Unit: 1°C/°F (0 to 399°C/°F) | K8AB-TH11S | |||
Thermocouple | Unit: 10°C/°F (See note 1.) | K8AB-TH12S |
last update: October 11, 2012