* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: November 13, 2017
PLd/Safety Category 3(ISO13849-1)
A redundant safety system can be configured by using two E2E Proximity Sensors. The fault diagnosis function of the G9SX-LM provides a high level of safety.
* Use only the DC 3-wire PNP type E2E.
In normal operating mode, standstill is monitored to unlock the door.
In maintenance mode, low-speed operation is monitored to allow maintenance work.
Because the drive rotation is directly monitored, the G9SX-LM can also be used with Servomotors.