Floatless Level Switch (Compact, Plug-in Type)
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: August 6, 2015
Item | General-purpose
Controller 61F-GP-N |
High-temperature
Controller 61F-GP-NT |
Long-distance Controllers
61F-GP-NL 2KM (for 2 km) 61F-GP-NL 4KM (for 4 km) |
---|---|---|---|
Controlling materials
and operating conditions |
For control of
ordinary purified water or sewage water |
For control of ordinary
purified water or sewage where operating ambient temperature is high. |
For control of ordinary purified water in
cases where the distance between sewage pumps and water tanks or between receiver tanks and supply tanks is long or where remote control is required. |
Supply voltage | 24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz | ||
Operating voltage range | 85% to 110% of rated voltage | ||
Interelectrode voltage | 8 VAC | ||
Interelectrode current | Approx. 1 mA AC max. | ||
Power consumption | Approx. 3.5 VA max. | ||
Interelectrode operate
resistance |
0 to approx. 4 kΩ | 0 to approx. 4 kΩ | 0 to approx. 1.3 kΩ (for 2 km)
0 to approx. 0.5 kΩ (for 4 km) |
Interelectrode release
resistance |
Approx. 15 k to ∞ Ω | Approx. 15 k to ∞ Ω | 4 k to ∞ Ω (for 2 km)
2.5 k to ∞ Ω (for 4 km) |
Response time | Operate:80 ms max.
Release:160 ms max. |
||
Cable length *1 | 1 km max. | 600 m max. | 2 km max.
4 km max. |
Control output | 1 A, 250 VAC (Inductive load: cosφ = 0.4)
3 A, 250 VAC (Resistive load) |
||
Ambient temperature | Operating:-10 to 55°C (-10 to 70°C for high-temperature controller) | ||
Ambient humidity | Operating:45% to 85% RH | ||
Insulation resistance
*2 |
100 MΩ min. (at 500 VDC) | ||
Dielectric strength *2 | 2000 VAC, 50/60 Hz for 1 min. | ||
Life expectancy | Electrical: 100,000 operations min.
Mechanical: 5,000,000 operations min. |
||
Weight | Approx. 155 g | ||
Accessories | Hold-down clip PFC-N8 | ||
Approved standards | UL508, CSA C22.2 No.14, EN61010-1, EN61326-1 Industrial electromagnetic environment |
Item | High-sensitivity
Controller 61F-GP-NH *4 |
Low-sensitivity
Controller 61F-GP-ND |
Two-wire Controller
61F-GP-NR |
---|---|---|---|
Controlling materials
and operating conditions |
For control of liquids with
high specific resistance such as distilled water |
For control of liquids with low
specific resistance such as salt water, sewage water, acid chemicals, alkali chemicals |
For control of ordinary purified
water or sewage water used in combination with Two-wire Electrode Holder (incorporating a resistor of 6.8 kΩ) |
Supply voltage | 24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz | ||
Operating voltage range | 85% to 110% of rated voltage | ||
Interelectrode voltage | 8 VAC | ||
Interelectrode current | Approx. 0.12 mA AC max. | Approx. 1 mA AC max. | |
Power consumption | Approx. 3.5 VA max. | ||
Interelectrode operate
resistance |
Approx. 10 kΩ to
approx. 40 kΩ *3 |
0 to approx. 1.3 kΩ | 0 to approx. 2 kΩ |
Interelectrode release
resistance |
Approx. 100 k to ∞ Ω | Approx. 4 k to ∞ Ω | Approx. 15 k to ∞ Ω |
Response time | Operate:80 ms max.
Release:160 ms max. |
||
Cable length *1 | 50 m max. | 1 km max. | 800 m max. |
Control output | 1 A, 250 VAC (Inductive load: cosφ = 0.4)
3 A, 250 VAC (Resistive load) |
||
Ambient temperature | Operating:-10 to 55°C (-10 to 70°C for high-temperature controller) | ||
Ambient humidity | Operating:45% to 85% RH | ||
Insulation resistance *2 | 100 MΩ min. (at 500 VDC) | ||
Dielectric strength *2 | 2000 VAC, 50/60 Hz for 1 min. | ||
Life expectancy | Electrical: 100,000 operations min.
Mechanical: 5,000,000 operations min. |
||
Weight | Approx. 155 g | ||
Accessories | Hold-down clip PFC-N8 | ||
Approved standards | UL508, CSA C22.2 No.14, EN61010-1, EN61326-1 Industrial electromagnetic environment |
Item | General-purpose
Controller 61F-GP-N8 61F-GP-N8Y *4 |
Long-distance
Controllers 61F-GP-N8L 2KM (for 2 km) 61F-GP-N8L 4KM (for 4 km) |
High-sensitivity
Controllers 61F-GP-N8H 61F-GP-N8HY *4 |
---|---|---|---|
Controlling materials
and operating conditions |
For control of ordinary
purified water or sewage water |
For control of ordinary purified
water in cases where the distance between sewage pumps and water tanks or between receiver tanks and supply tanks is long or where remote control is required. |
For control of liquids with
high specific resistance such as distilled water |
Supply voltage | 24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz | ||
Operating voltage range | 85% to 110% of rated voltage | ||
Interelectrode voltage | 8 VAC | 24 VAC | |
Interelectrode current | Approx. 1 mA AC max. | Approx. 0.4 mA AC max. | |
Power consumption | Approx. 3.5 VA max. | ||
Interelectrode operate
resistance |
0 to approx. 4 kΩ | 0 to 1.3 kΩ (for 2 km)
0 to 0.5 kΩ (for 4 km) |
Approx. 15 kΩ to
approx. 70 kΩ *3 |
Interelectrode release
resistance |
Approx. 15 k to ∞ Ω | 4 k to ∞ Ω (for 2 km)
2.5 k to ∞ Ω (for 4 km) |
Approx. 300 k to ∞ Ω |
Response time | Operate: 80 ms max.
Release: 160 ms max. |
||
Cable length *1 | 1 km max. | 2 km max.
4 km max. |
50 m max. |
Control output | 1 A, 250 VAC (Inductive load: cosφ = 0.4)
3 A, 250 VAC (Resistive load) |
||
Ambient temperature | Operating: -10 to 55°C | ||
Ambient humidity | Operating: 45% to 85% RH | ||
Insulation resistance *2 | 100 MΩ min. (at 500 VDC) | ||
Dielectric strength *2 | 2000 VAC, 50/60 Hz for 1 min. | ||
Life expectancy | Electrical: 100,000 operations min.
Mechanical: 5,000,000 operations min. |
||
Weight | Approx. 155 g | ||
Accessories | Hold-down clip PFC-N8 | ||
Approved standards | UL508, CSA C22.2 No.14, EN61010-1, EN61326-1 Industrial electromagnetic environment |
Item | Low-sensitivity
Controller 61F-GP-N8D |
Two-wire Controller
61F-GP-N8R |
Variable Sensitivity Controller
61F-GP-N8-V50 |
---|---|---|---|
Controlling materials
and operating conditions |
For control of liquids
with low specific resistance such as salt water, sewage water, acid chemicals, alkali chemicals |
For control of ordinary
purified water or sewage water used in combination with Two-wire Electrode Holder (incorporating a resistor of 6.8 kΩ) |
For control of cases where variable
sensitivity control is required such as detection of froth on the surface of a liquid, control of soil moisture content, or detection of degree of water pollution |
Supply voltage | 24, 100, 110, 120, 200, 220, 230 or 240 VAC;
50/60 Hz |
24, 110, 220 or 240 VAC; 50/60 Hz | |
Operating voltage range | 85% to 110% of rated voltage | ||
Interelectrode voltage | 8 VAC | 24 VAC | |
Interelectrode current | Approx. 1 mA AC max. | Approx. 3 mA AC max. | |
Power consumption | Approx. 3.5 VA max. | ||
Interelectrode operate
resistance |
0 to approx. 1.3 kΩ | 0 to approx. 2 kΩ | 0 to 50 kΩ (Variable) |
Interelectrode release
resistance |
Approx. 4 k to ∞ Ω | Approx. 15 k to ∞ Ω | Operating resistance +50 kΩ max. |
Response time | Operate: 80 ms max.
Release: 160 ms max. |
||
Cable length *1 | 1 km max. | 800 m max. | 50 m max. |
Control output | 1 A, 250 VAC (Inductive load: cosφ = 0.4)
3 A, 250 VAC (Resistive load) |
||
Ambient temperature | Operating: -10 to 55°C | ||
Ambient humidity | Operating: 45% to 85% RH | ||
Insulation resistance *2 | 100 MΩ min. (at 500 VDC) | ||
Dielectric strength *2 | 2000 VAC, 50/60 Hz for 1 min. | ||
Life expectancy | Electrical: 100,000 operations min.
Mechanical: 5,000,000 operations min. |
||
Weight | Approx. 155 g | ||
Accessories | Hold-down clip PFC-N8 | ||
Approved standards | UL508, CSA C22.2 No.14, EN61010-1, EN61326-1 Industrial electromagnetic environment |
last update: August 6, 2015