NX-series Analog I/O Unit
last update: October 19, 2020
Item | Specification | |
---|---|---|
Enclosure | Mounted in a panel | |
Grounding method | Ground to 100 Ω or less | |
Operating
environment |
Ambient operating temperature | 0 to 55°C |
Ambient operating humidity | 10% to 95% (with no condensation or icing) | |
Atmosphere | Must be free from corrosive gases. | |
Ambient storage temperature | -25 to 70°C (with no condensation or icing) | |
Altitude | 2,000 m max. | |
Pollution degree | 2 or less: Meets IEC 61010-2-201. | |
Noise immunity | 2 kV on power supply line (Conforms to IEC61000-4-4.) | |
Overvoltage category | Category II: Meets IEC 61010-2-201. | |
EMC immunity level | Zone B | |
Vibration resistance | Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) |
|
Shock resistance | Conforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and
Z directions |
|
Applicable standards * | cULus: Listed (UL508), ANSI/ISA 12.12.01, EU: EN 61131-2, C-Tick
or RCM, KC Registration, NK, LR |
* Ask your OMRON representative for the most recent applicable standards for each model.
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD2603 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Single-ended input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD2604 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD2608 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.2% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD3603 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Single-ended input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD3604 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD3608 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.2% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD4603 | |
---|---|---|---|---|
Number of points | 8 points | External connection
terminals |
Screwless clamping terminal block
(16 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Single-ended input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOG: 0.1 A/terminal max. | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.15 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD4604 | |
---|---|---|---|---|
Number of points | 8 points | External connection
terminals |
Screwless clamping terminal block
(16 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.15 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(voltage input type) |
Model | NX-AD4608 | |
---|---|---|---|---|
Number of points | 8 points | External connection
terminals |
Screwless clamping terminal block
(16 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | -10 to +10 V | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±15 V | |||
Input impedance | 1 MΩ min. | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.2% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.15 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Not supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD2203 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Single-ended input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 250 Ω | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD2204 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 250 Ω | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD2208 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 250 Ω | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.2% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD3203 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Single-ended input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 250 Ω | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD3204 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 250 Ω | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD3208 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 250 Ω | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.2% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.30 W max. • Connected to a Communi- cations Coupler Unit 0.95 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD4203 | |
---|---|---|---|---|
Number of points | 8 points | External connection
terminals |
Screwless clamping terminal block
(16 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Single-ended input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 85 Ω | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max. | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD4204 | |
---|---|---|---|---|
Number of points | 8 points | External connection
terminals |
Screwless clamping terminal block
(16 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 85 Ω | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.2% (full scale) | ||
0 to 55℃ | ±0.4% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Input Unit
(current input type) |
Model | NX-AD4208 | |
---|---|---|---|---|
Number of points | 8 points | External connection
terminals |
Screwless clamping terminal block
(16 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Input method | Differential Input | |
Input range | 4 to 20 mA | |||
Input conversion
range |
-5 to 105% (full scale) | |||
Absolute maximum
rating |
±30 mA | |||
Input impedance | 85 Ω | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.2% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
No supply | Current capacity of
I/O power supply terminal |
Without I/O power supply terminals | |
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
|||
Input disconnection
detection |
Supported. |
Unit name | Analog Output Unit
(voltage output type) |
Model | NX-DA2603 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | -10 to +10 V | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
5 kΩ min. | |||
Output impedance | 0.5 Ω max. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.3% (full scale) | ||
0 to 55℃ | ±0.5% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
Unit name | Analog Output Unit
(voltage output type) |
Model | NX-DA2605 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | -10 to +10 V | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
5 kΩ min. | |||
Output impedance | 0.5 Ω max. | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.3% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
Unit name | Analog Output Unit
(voltage output type) |
Model | NX-DA3603 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | -10 to +10 V | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
5 kΩ min. | |||
Output impedance | 0.5 Ω max. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.3% (full scale) | ||
0 to 55℃ | ±0.5% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.25 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
Unit name | Analog Output Unit
(voltage output type) |
Model | NX-DA3605 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | -10 to +10 V | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
5 kΩ min. | |||
Output impedance | 0.5 Ω max. | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.3% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 1.60 W max. • Connected to a Communi- cations Coupler Unit 1.25 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
Terminal connection
diagram |
![]() |
Unit name | Analog Output Unit
(current output type) |
Model | NX-DA2203 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | 4 to 20 mA | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
600 Ω max. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.3% (full scale) | ||
0 to 55℃ | ±0.6% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.75 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
Terminal connection
diagram |
![]() |
Unit name | Analog Output Unit
(current output type) |
Model | NX-DA2205 | |
---|---|---|---|---|
Number of points | 2 points | External connection
terminals |
Screwless clamping terminal block
(8 terminals) |
|
I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | 4 to 20 mA | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
600 Ω max. | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.3% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.75 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
Terminal connection
diagram |
![]() |
Unit name | Analog Output Unit
(current output type) |
Model | NX-DA3203 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | 4 to 20 mA | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
350 Ω max. | |||
Resolution | 1/8000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.3% (full scale) | ||
0 to 55℃ | ±0.6% (full scale) | |||
Conversion time | 250 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.80 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
Terminal connection
diagram |
![]() |
Unit name | Analog Output Unit
(current output type) |
Model | NX-DA3205 | |
---|---|---|---|---|
Number of points | 4 points | External connection
terminals |
Screwless clamping terminal block
(12 terminals) |
|
I/O refreshing method | Free-Run refreshing | |||
Indicator | TS indicator
![]() |
Output range | 4 to 20 mA | |
Output conversion
range |
-5 to 105% (full scale) | |||
Allowable load
resistance |
350 Ω max. | |||
Resolution | 1/30000 (full scale) | |||
Overall
accuracy |
25℃ | ±0.1% (full scale) | ||
0 to 55℃ | ±0.3% (full scale) | |||
Conversion time | 10 μs/point | |||
Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus:
Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
Insulation resistance | 20 MΩ min. between isolated
circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits
for 1 minute at a leakage current of 5 mA max. |
|
I/O power supply
method |
Supply from the NX bus | Current capacity of
I/O power supply terminal |
IOV: 0.1 A/terminal max.,
IOG: 0.1 A/terminal max. |
|
NX Unit power
consumption |
• Connected to a CPU Unit or
Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.80 W max. |
I/O current
consumption |
No consumption | |
Weight | 70 g max. | |||
Circuit layout | ![]() |
|||
Installation orientation
and restrictions |
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
Terminal connection
diagram |
![]() |
Refer to the user's manual for the CPU Unit details on the CPU Units to which NX Units can be connected.
NX Units | Corresponding unit versions/versions | ||
---|---|---|---|
Model | Unit version | CPU Unit | Sysmac Studio |
NX-AD[][][][]
NX-DA[][][][] |
Ver.1.0 | Ver.1.13 | Ver.1.17 |
NX Units | Corresponding unit versions/versions | |||
---|---|---|---|---|
Model | Unit version | EtherCAT Coupler Unit | CPU Unit or Industrial PC | Sysmac Studio |
NX-AD[][][][]
NX-DA[][][][] |
Ver.1.0 | Ver.1.0 | Ver.1.05 | Ver.1.06 |
NX Units | Corresponding unit versions/versions | ||||||
---|---|---|---|---|---|---|---|
Model | Unit
version |
Application with an NJ/NX/NY-series
Controller *1 |
Application with a CS/CJ/CP-series
PLC *2 |
||||
EtherNet/IP
Coupler Unit |
CPU Unit or
Industrial PC |
Sysmac
Studio |
EtherNet/IP
Coupler Unit |
Sysmac
Studio |
NX-IO
Configurator *3 |
||
NX-AD[][][][]
NX-DA[][][][] |
Ver.1.0 | Ver. 1.2 | Ver. 1.14 | Ver. 1.19 | Ver. 1.0 | Ver. 1.10 | Ver. 1.00 |
NX Units | Corresponding unit versions/versions | ||
---|---|---|---|
Model | Unit version | Communication Control Unit | Sysmac Studio |
NX-AD[][][][]
NX-DA[][][][] |
Ver.1.0 | Ver.1.00 | Ver.1.24 |
last update: October 19, 2020