Page top

Industrial Automation

Industrial Automation

Discontinued On Mar. 2018

E2Q2

Rectangular Proximity Sensor

E2Q2

Change the Sensing Direction Freely

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

Shielding Shielded Unshielded Shielded Unshielded
Model E2Q2-N20[]3-H E2Q2-N30M[]3-H E2Q2-N15Y4-H E2Q2-N30MY4-H
Sensing distance 20 mm±10% 30 mm±10% 15 mm±10% 30 mm±10%
Set distance 0 to 16 mm 0 to 24 mm 0 to 12 mm 0 to 24 mm
Differential travel 15% max. of sensing distance
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object Iron, 60 × 60 ×
1 mm
Iron, 90 × 90 × 1 mm Iron, 60 × 60 ×
1 mm
Iron, 90 × 90 × 1 mm
Response frequency 150 Hz 100 Hz 20 Hz
Power supply voltage
(operating voltage range)
12 to 48 VDC (10 to 60 VDC), ripple (p-p):
10% max.
24 to 240 VAC (20 to 253 VAC), 50/60 Hz
Current consumption/
Leakage current
20 mA max. 1.7 mA max
Refer to Engineering Data on Data Sheet.
Control
output
Switching
capacity
200 mA max. 8 to 500 mA
Residual
voltage
3 V max. with a 200 mA load current Refer to Engineering Data on Data Sheet.
Indicators Power indicator (green)
Detection indicator (yellow)
Power indicator (green)
Operation indicator (yellow)
Operation mode (with
sensing object approaching)
E3 Models: NPN NO+NC
F3 Models: PNP NO+NC
Refer to the timing charts under I/O Circuit
Diagrams on Data Sheet for details.
AC: NO or NC (selectable)
Refer to the timing charts under I/O Circuit
Diagrams on Data Sheet for details.
Protection circuits Reverse polarity protection, load short-
circuit protection
-
Ambient temperature Operating: -25 to 70°C (with no icing or condensation)
Storage: -40 to 70°C (with no icing or condensation)
Ambient humidity Operating: 35% to 85% (with no condensation)
Storage: 35% to 95% (with no condensation)
Temperature
influence
Shielded
model
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Unshielded
model
±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±2% max. of sensing distance at within a range of ±10% of rated power supply voltage
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength E[] Model and F[] Model: 1,000 VAC, 50/60 Hz for 1 min. between current-carrying parts
and case
Y Model: 4,000 VAC, 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC IP67 *
Connection method Terminal block
Weight Approx. 240 g
Materials Case Polybutylene terephthalate (PBT)
Terminal
block
Polybutylene terephthalate (PBT)
Sensing
surface
Polybutylene terephthalate (PBT)

* When the recommended cable clamp is used.