Rectangular Proximity Sensor
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: October 10, 2013
Shielding | Shielded | Unshielded | Shielded | Unshielded | |
---|---|---|---|---|---|
Model | E2Q2-N20[]3-H | E2Q2-N30M[]3-H | E2Q2-N15Y4-H | E2Q2-N30MY4-H | |
Sensing distance | 20 mm±10% | 30 mm±10% | 15 mm±10% | 30 mm±10% | |
Set distance | 0 to 16 mm | 0 to 24 mm | 0 to 12 mm | 0 to 24 mm | |
Differential travel | 15% max. of sensing distance | ||||
Sensing object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 60 × 60 ×
1 mm |
Iron, 90 × 90 × 1 mm | Iron, 60 × 60 ×
1 mm |
Iron, 90 × 90 × 1 mm | |
Response frequency | 150 Hz | 100 Hz | 20 Hz | ||
Power supply voltage
(operating voltage range) |
12 to 48 VDC (10 to 60 VDC), ripple (p-p):
10% max. |
24 to 240 VAC (20 to 253 VAC), 50/60 Hz | |||
Current consumption/
Leakage current |
20 mA max. | 1.7 mA max
Refer to Engineering Data on Data Sheet. |
|||
Control
output |
Switching
capacity |
200 mA max. | 8 to 500 mA | ||
Residual
voltage |
3 V max. with a 200 mA load current | Refer to Engineering Data on Data Sheet. | |||
Indicators | Power indicator (green)
Detection indicator (yellow) |
Power indicator (green)
Operation indicator (yellow) |
|||
Operation mode (with
sensing object approaching) |
E3 Models: NPN NO+NC
F3 Models: PNP NO+NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
AC: NO or NC (selectable)
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
|||
Protection circuits | Reverse polarity protection, load short-
circuit protection |
- | |||
Ambient temperature | Operating: -25 to 70°C (with no icing or condensation)
Storage: -40 to 70°C (with no icing or condensation) |
||||
Ambient humidity | Operating: 35% to 85% (with no condensation)
Storage: 35% to 95% (with no condensation) |
||||
Temperature
influence |
Shielded
model |
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Unshielded
model |
±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±2% max. of sensing distance at within a range of ±10% of rated power supply voltage | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | E[] Model and F[] Model: 1,000 VAC, 50/60 Hz for 1 min. between current-carrying parts
and case |
||||
Y Model: 4,000 VAC, 50/60 Hz for 1 min. between current-carrying parts and case | |||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | IEC IP67 * | ||||
Connection method | Terminal block | ||||
Weight | Approx. 240 g | ||||
Materials | Case | Polybutylene terephthalate (PBT) | |||
Terminal
block |
Polybutylene terephthalate (PBT) | ||||
Sensing
surface |
Polybutylene terephthalate (PBT) |
* When the recommended cable clamp is used.
last update: October 10, 2013