Latching Relay
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: September 24, 2012
Rated
voltage |
Set coil | Reset coil | Set
voltage |
Reset
voltage |
Max.
voltage |
Power
consumption |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|
Rated current | Coil re-
sistance |
Rated current | Coil re-
sistance |
Set
coil |
Reset
coil |
||||||
50 Hz | 60 Hz | 50 Hz | 60 Hz | ||||||||
12 VAC | 162 mA | 158 mA | 28 Ω | 40 mA | 39 mA | 125 Ω | 80%
max. of rated voltage |
80%
max. of rated voltage |
110%
of rated voltage |
Approx.
1.6 to 2.0 VA |
Approx.
0.5 to 1.2 VA |
24 VAC | 66 mA | 64 mA | 145 Ω | 22.6 mA | 22 mA | 460 Ω | |||||
50 VAC | 34 mA | 33 mA | 590 Ω | 11.3 mA | 11 mA | 1,900 Ω | |||||
100 VAC | 19 mA | 18.5 mA | 2,150 Ω | 12.3 mA | 12 mA | 3,600 Ω | |||||
6 VDC | 360 mA | 14 Ω | 160 mA | 32 Ω | Approx.
2.0 to 2.2 W |
Approx.
1.0 to 1.2 W |
|||||
12 VDC | 170 mA | 65 Ω | 85 mA | 125 Ω | |||||||
24 VDC | 85 mA | 270 Ω | 50 mA | 460 Ω | |||||||
48 VDC | 44 mA | 1,050 Ω | 24 mA | 1,900 Ω |
Rated voltage | Connected coil voltage | External resistor | |||
---|---|---|---|---|---|
Set coil | Reset coil | ||||
Resistance | Capacity | Resistance | Capacity | ||
110 VAC | 100 VAC | 0.27 kΩ | 0.5 W min. | 0.39 kΩ | 1/4 W min. |
200 VAC | 100 VAC | 2.7 kΩ | 5 W min. | 8.2 kΩ | 3 W min. |
220 VAC | 100 VAC | 3.3 kΩ | 6 W min. | 9.1 kΩ | 3 W min. |
100 VDC | 48 VDC | 1.1 kΩ | 10 W min. | 2.0 kΩ | 6 W min. |
Note: Use a resistor having the above resistance value with tolerances of ±10% for external connection.
Load | Resistive load (cosφ = 1) | Inductive load (cosφ = 0.4) (L/R = 7 ms) |
---|---|---|
Contact type | Crossbar bifurcated | |
Contact material | Movable: Au-clad AgPd
Fixed: AgPd |
|
Rated load | 0.3 A at 110 VAC
0.5 A at 24 VDC |
0.2 A at 110 VAC
0.3 A at 24 VDC |
Rated carry current | 3 A | |
Max. switching voltage | 250 VAC, 125 VDC |
Contact resistance
(see note 2) |
100 mΩ max. |
---|---|
Set time
(see note 3) |
AC: 25 ms max.; DC: 15 ms max. |
Reset time
(see note 3) |
AC: 25 ms max.; DC: 15 ms max. |
Min. pulse width | AC: 50 ms; DC: 30 ms |
Max. operating frequency | Mechanical: 18,000 operations/hour
Electrical: 1,800 operations/hour (under rated load) |
Insulation resistance
(see note 4) |
100 MΩ min. (at 500 VDC) |
Dielectric strength | 1,500 VAC, 50/60 Hz for 1 minute between coil and contact (700 VAC between contacts
of same pole) (1,000 VAC between set and reset coils) |
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) (for contact malfunction); 3.0-mm double amplitude (for armature malfunction) |
Shock resistance | Destruction: 1,000 m/s2
Malfunction: 100 m/s2, 300 m/s2 |
Endurance | Mechanical: 100,000,000 operations min. (at operating frequency of 18,000 operations/
hour) Electrical: 5,000,000 operations min. (under rated load and at operating frequency of 1,800 operations/hour) (see note 5) |
Error rate (level P)
(Reference value) (see note 6) |
1 mA at 100 mVDC |
Ambient temperature | Operating: -10°C to 40°C (with no icing or condensation) |
Ambient humidity | Operating: 5% to 85% |
Weight | Approx. 38 g |
last update: September 24, 2012