Temperature Sensor (Low-cost Models)
last update: January 5, 2018
Element type | Pt100 |
---|---|
Conductor type | 3-conductor system |
Class | Class B |
Protective tubing material | SUS304 |
Sensor length | 30 mm |
Max. detectable temperature | 250°C |
Temperature range | -50°C to 250°C |
Lead wire | Fluororesin-covered wire (PFA) with 1.0 outer dia.
7/0.18 -50°C to 150°C |
Element wire | Pt100 |
---|---|
Conductor type | 3-conductor system |
Class | Class B |
Protective tubing material | SUS304 |
Sensor length | 30 mm |
Max. detectable temperature | 250°C |
Temperature range | -50°C to 250°C |
Lead wire | Fluororesin-covered wire (PFA) with 1.0 outer dia.
7/0.18 -50°C to 150°C |
Element type | Pt100 |
---|---|
Conductor type | 3-conductor system |
Class | Class B |
Protective tubing material | SUS316 |
Max. detectable temperature | 250°C |
Temperature range | 0°C to 250°C |
Lead wire | Fluororesin-covered wire (PFA) with 1.0 outer dia.
7/0.18 -50°C to 150°C |
Element type | K (CA), J (IC) |
---|---|
Element dia. | 0.65 mm (single wire) |
Class | Class 2 (0.75) |
Protective tubing material | SUS304 |
Thermal contact | Non-grounded type |
Temperature range | 0°C to 400°C: K (CA)
0°C to 350°C: J (IC) |
Lead wire | Fully glass-wool-covered compensating cable and external dimensions of approx. 5.1 x 3.0
4/0.65 0°C to 180°C |
Note: The sleeve resists temperatures ranging between 0°C and 100°C.
Element type | K (CA), J (IC) |
---|---|
Element dia. | 0.65 mm (single wire) |
Class | Class 2 (0.75) |
Protective tubing material | SUS304 |
Thermal contact | Grounded type |
Temperature range | 0°C to 400°C: K (CA)
0°C to 350°C: J (IC) |
Lead wire | Fully glass-wool-covered with external copper shield and external dimensions of
approx. 3.1 x 2.0 1/0.65 0°C to 180°C |
Terminal shape | Y-type crimp terminal for M3.5 |
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. Specify the type of screw (i.e., M6, M8, or W1/4) when ordering.
3. The thermocouple is not of airtight construction.
4. OMRON recommends that the tip of the thermocouple is touching the sensing object.
Element type | K (CA), J (IC) |
---|---|
Class | Class 2 (0.75) |
Protective tubing material | SUS304 |
Thermal contact | Grounded type |
Temperature range | 0°C to 350°C: K (CA)
0°C to 350°C: J (IC) |
Lead wire | Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0
1/0.32 0°C to 150°C |
Element type | K (CA) |
---|---|
Class | Class 2 (0.75) |
Protective tubing material | SUS304 |
Thermal contact | Grounded type |
Temperature range | 0°C to 350°C: K (CA) |
Lead wire | Fluororesin-covered thermocouple wire (PFA) with external dimensions of 2.5 x 1.5
1/0.65 0°C to 150°C |
Element type | K (CA), J (IC) |
---|---|
Class | Class 2 (0.75) |
Protective tubing material | SUS304 |
Thermal contact | Grounded type |
Temperature range | 0°C to 350°C: K (CA)
0°C to 350°C: J (IC) |
Lead wire | Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0
1/0.3 0°C to 150°C |
Element type | K (CA) |
---|---|
Class | Class 2 (0.75) |
Protective tubing material | SUS304 |
Thermal contact | Grounded type |
Temperature range | 0°C to 350°C: K (CA) |
Lead wire | Fluororesin-covered thermocouple wire (PFA) with external dimensions of 2.5 x 1.5
1/0.65 0°C to 150°C |
Element type | K (CA), J (IC) |
---|---|
Class | Class 2 (0.75) |
Protective tubing material | SUS304 |
Thermal contact | Non-grounded type |
Temperature range | 0°C to 350°C: K (CA)
0°C to 200°C: J (IC) |
Lead wire | Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0
1/0.32 0°C to 180°C |
last update: January 5, 2018