Measuring & Monitoring Relays
last update: September 5, 2013
Setting range | Supply voltage | Model |
---|---|---|
2 to 20 mA AC/DC,
10 to 100 mA AC/DC 50 to 500 mA AC/DC |
24 VAC/DC | K8AK-AS1 24 VAC/DC |
100 to 240 VAC | K8AK-AS1 100-240 VAC | |
0.1 to 1 A AC/DC,
0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC |
24 VAC/DC | K8AK-AS2 24 VAC/DC |
100 to 240 VAC | K8AK-AS2 100-240 VAC | |
10 to 100 A AC *,
20 to 200 A AC * |
24 VAC/DC | K8AK-AS3 24 VAC/DC |
100 to 240 VAC | K8AK-AS3 100-240 VAC |
Appearance | Input range | Applicable Relay | Model |
---|---|---|---|
10 to 100 A AC,
20 to 200 A AC |
K8AK-AS3 | K8AC-CT200L |
Appearance | CT current on secondary side | Applicable Relay |
---|---|---|
0 to 1 A AC,
0 to 5 A AC |
K8AK-AS2 |
* If you use a commercially available CT, do not exceed the overload capacity of the K8AK-AS2.
Setting range | Supply voltage | Model |
---|---|---|
2 to 20 mA AC/DC
10 to 100 mA AC/DC 50 to 500 mA AC/DC |
24 VAC/DC | K8AK-AW1 24 VAC/DC |
100 to 240 VAC | K8AK-AW1 100-240 VAC | |
0.1 to 1 A AC/DC
0.5 to 5 A AC/DC |
24 VAC/DC | K8AK-AW2 24 VAC/DC |
100 to 240 VAC | K8AK-AW2 100-240 VAC | |
10 to 100 A AC *
20 to 200 A AC * |
24 VAC/DC | K8AK-AW3 24 VAC/DC |
100 to 240 VAC | K8AK-AW3 100-240 VAC |
Appearance | Input range | Applicable Relay | Model |
---|---|---|---|
10 to 100 A AC,
20 to 200 A AC |
K8AK-AW3 | K8AC-CT200L |
Appearance | CT current on secondary side | Applicable Relay |
---|---|---|
0 to 1 A AC,
0 to 5 A AC |
K8AK-AW2 |
* If you use a commercially available CT, do not exceed the overload capacity of the K8AK-AW2.
Setting range | Control power supply voltage | Model |
---|---|---|
1 to 10 V AC/DC
3 to 30 V AC/DC 15 to 150 V AC/DC |
24 VAC/DC | K8AK-VS2 24 VAC/DC |
100 to 240 VAC | K8AK-VS2 100-240 VAC | |
20 to 200 V AC/DC
30 to 300 V AC/DC 60 to 600 V AC/DC |
24 VAC/DC | K8AK-VS3 24 VAC/DC |
100 to 240 VAC | K8AK-VS3 100-240 VAC |
Setting range | Supply voltage | Model |
---|---|---|
1 to 10 V AC/DC
3 to 30 V AC/DC 15 to 150 V AC/DC |
24 VAC/DC | K8AK-VW2 24 VAC/DC |
100 to 240 VAC | K8AK-VW2 100 to 240 VAC | |
20 to 200 V AC/DC
30 to 300 V AC/DC 60 to 600 V AC/DC |
24 VAC/DC | K8AK-VW3 24 VAC/DC |
100 to 240 VAC | K8AK-VW3 100 to 240 VAC |
Function | Rated input voltage * | Relay output | Model |
---|---|---|---|
Phase sequence and phase loss monitoring | 3-phase, 3-wire 200 to 480 VAC | SPDT × 1 | K8DS-PH1 |
* The power supply is shared with the rated input voltage.
Function | Rated input voltage * | Relay output | Model |
---|---|---|---|
Phase sequence and phase loss monitoring | 3-phase, 3-wire 200 to 480 VAC | DPDT ×1 | K8AK-PH1 |
* The power supply is shared with the rated input voltage.
Rated input * | Model | |
---|---|---|
3-phase 3-wire mode | 200, 220, 230, 240 VAC | K8AK-PW1 |
3-phase 4-wire mode | 115, 127, 133, 138 VAC | |
3-phase 3-wire mode | 380, 400, 415, 480 VAC | K8AK-PW2 |
3-phase 4-wire mode | 220, 230, 240, 277 VAC |
Note: Three-phase, three-wire or four-wire and the input range are switched using a DIP switch.
* The power supply voltage is the same as the rated input voltage.
Rated input * | Model | |
---|---|---|
3-phase 3-wire mode | 200, 220, 230, 240 VAC | K8AK-PM1 |
3-phase 4-wire mode | 115, 127, 133, 138 VAC | |
3-phase 3-wire mode | 380, 400, 415, 480 VAC | K8AK-PM2 |
3-phase 4-wire mode | 220, 230, 240, 277 VAC |
Note: Three-phase 3-wire or 4-wire and the input range are switched using a DIP switch.
* The power supply is shared with the rated input voltage.
Rated input * | Model | |
---|---|---|
3-phase 3-wire mode | 200, 220, 230, 240 VAC | K8AK-PA1 |
3-phase 4-wire mode | 115, 127, 133, 138 VAC | |
3-phase 3-wire mode | 380, 400, 415, 480 VAC | K8AK-PA2 |
3-phase 4-wire mode | 220, 230, 240, 277 VAC |
Note: Three-phase, three-wire or four-wire and the input range are switched using a DIP switch.
* The power supply voltage is the same as the rated input voltage.
Power
supply |
Type | Output
relays |
Input types | Setting units
(setting range) |
Model |
---|---|---|---|---|---|
100 to
240 VAC |
Temperature
input |
1 relay | Thermocouple or platinum
resistance thermometer |
Setting unit: 1°C or 1°F
(0 to 999°C/°F) |
K8AK-TH11S 100-240VAC |
Thermocouple | Setting unit: 10°C/°F * | K8AK-TH12S 100-240VAC | |||
24 VAC/DC | Thermocouple or platinum
resistance thermometer |
Setting unit: 1°C or 1°F
(0 to 999°C/°F) |
K8AK-TH11S 24VAC/DC | ||
Thermocouple | Setting unit: 10°C/°F * | K8AK-TH12S 24VAC/DC |
* Refer to Setting Ranges on Catalog for the setting ranges.
Note: When ordering, designate the power supply specification. Different Relay models are used for 100 to 240 VAC and 24 VAC/VDC.
Power supply voltage | Model |
---|---|
24 VAC/DC | K8AK-LS1 24 VAC/DC |
100 to 240 VAC | K8AK-LS1 100-240 VAC |
Application | For general-
purpose use, such as water supply lines |
For areas
with limited space |
For liquids
with low resistance |
When
mounting strength is required |
For
resistance to high- temperature or high- pressure liquids |
For
resistance against corrosion |
For
installation at long distances from the liquid level |
---|---|---|---|---|---|---|---|
Model | PS-3S/-4S/-5S
(2-wire models are also available) |
PS-31
SUS304, 300 mm |
BF-1 | BF-3/-5 | BS-1 | BS-1T | PH-1/-2 |
Appearance |
Electrode Rods are available in sets with the connection nuts, lock nuts, and tightening screws.
Application | Purified water service, industrial water, and sewage | Purified water service, industrial water, sewage, and
weak alkaline solutions |
---|---|---|
Model | F03-60 SUS304 | F03-60 SUS316 |
Item | Model | |
---|---|---|
Protective Cover
(Electrode Holders for the PS or BF Series) |
F03-11 | |
Mounting Piece (Electrode Holder for the PS Series) | F03-12 | |
Separator (to prevent contact between electrodes) | F03-14 1P (one pole)
F03-14 3P (three poles) F03-14 5P (five poles) |
last update: September 5, 2013