Lighted Pushbutton Switch (Square) Ultra Bright LED Type
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: October 15, 2013
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC
250 VAC |
3
2 |
1
0.7 |
0.7
0.5 |
2
1.5 |
1.5
1 |
1
0.7 |
||
8 VDC
14 VDC 30 VDC 125 VDC 250 VDC |
3
3 2 0.4 0.2 |
1
1 1 0.05 0.03 |
2
1.5 1.5 0.4 0.2 |
1.5
1.5 1 0.05 0.03 |
Rating | 0.1 A at 30 VDC (resistive load);
0.1 A at 125 VAC (resistive load) |
---|---|
Minimum applicable load | 1 mA at 5 VDC |
Applied voltage | Rated voltage | Rated current |
---|---|---|
5 VDC±5% | 5 VDC | 8 mA |
12 VAC/VDC±5% | 12 VAC/VDC | |
24 VAC/VDC±5% | 24 VAC/VDC |
Operating
frequency |
Mechanical | Momentary operation models: 120 operations/min max. *1 |
---|---|---|
Electrical | 20 operations/min max. | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact
resistance |
Standard load | 50 mΩ max. (initial value) |
Microload | 50 mΩ max. (initial value) | |
Dielectric
strength |
Between terminals of same polarity | 1,000 VAC, 50/60 Hz for 1 minute |
Between terminals of different polarity | 2,000 VAC, 50/60 Hz for 1 minute | |
Between current-carrying metal part
and ground |
2,000 VAC, 50/60 Hz for 1 minute | |
Between each terminal and non-
current-carrying metal part |
2,000 VAC, 50/60 Hz for 1 minute | |
Between lamp terminals | 1,000 VAC, 50/60 Hz for 1 minute *2 | |
Vibration
resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *3 |
Shock
resistance |
Destruction | 500 m/s2 max. |
Malfunction | 200 m/s2 max. *3 | |
Life
expectancy |
Mechanical | Momentary operation models: 1,000,000 operations min.
Alternate operation models: 100,000 operations min. (One operation consists of set and reset operations.) |
Electrical | 100,000 operations min. (rated load) | |
Weight | Approx. 10 g | |
Inrush
current |
NC | Standard load: 10 A max. |
NO | Standard load: 10 A max. | |
Ambient operating temperature | -10 to 50°C (with no icing or condensation) | |
Ambient operating humidity | 35% to 85% RH | |
Ambient storage temperature | -25 to 65°C (with no icing or condensation) | |
Degree of protection | IP00 | |
Electric shock protection class | Class II | |
PTI (proof tracking index) | 175 | |
Pollution degree | 3 (IEC 60947-5-1) |
*1. With alternate operation models, 60 operations/min max. One operation cycle consists of set and reset operations.
*2. With no incandescent lamp or LED lamp mounted.
*3. Malfunction : 1 ms max.
Operation | Momentary operation models | Alternate operation models | |
---|---|---|---|
Operating characteristics | |||
Operating force | OF max. | 3.92 N | 4.90 N |
Releasing force | RF min. | 0.49 N | 0.294 N |
Total travel | TT | Approx. 3 mm | Approx. 3 mm |
Pretravel | PT max. | 2.2 mm | 2.2 mm |
Lock travel alternate | LTA min. | - | 0.5 mm |
Name | Contact Form |
---|---|
Double-throw contacts |
![]() |