Digital Temperature Controller (Simple Type) (48 × 96 mm)
last update: October 2, 2017
Control output 1 | Control
output 2 |
Auxiliary
output |
Commu-
nications |
Heater
burnout |
Event
inputs |
Power
supply voltage |
Model |
---|---|---|---|---|---|---|---|
Relay output | - | Two | - | - | - | 100 to
240 VAC |
E5EC-RX2ASM-800 |
Voltage output | - | E5EC-QX2ASM-800 | |||||
Linear current output | - | E5EC-CX2ASM-800 | |||||
Relay output | Relay output | E5EC-RR2ASM-800 | |||||
Voltage output | Relay output | E5EC-QR2ASM-800 | |||||
Linear current output | Relay output | E5EC-CR2ASM-800 | |||||
Relay output | - | 24 VAC/
VDC |
E5EC-RX2DSM-800 | ||||
Voltage output | - | E5EC-QX2DSM-800 | |||||
Linear current output | - | E5EC-CX2DSM-800 | |||||
Relay output | Relay output | E5EC-RR2DSM-800 | |||||
Voltage output | Relay output | E5EC-QR2DSM-800 | |||||
Linear current output | Relay output | E5EC-CR2DSM-800 | |||||
Relay output | Relay output | RS-485 | One | Two | 100 to
240 VAC |
E5EC-RR2ASM-808 | |
Voltage output | Relay output | E5EC-QR2ASM-808 | |||||
Relay output | Relay output | 24 VAC/
VDC |
E5EC-RR2DSM-808 | ||||
Voltage output | Relay output | E5EC-QR2DSM-808 | |||||
Relay output | Relay output | - | Four | 100 to
240 VAC |
E5EC-RR2ASM-810 | ||
Voltage output | Relay output | E5EC-QR2ASM-810 | |||||
Relay output | Relay output | 24 VAC/
VDC |
E5EC-RR2DSM-810 | ||||
Voltage output | Relay output | E5EC-QR2DSM-810 | |||||
Linear current output | Relay output | RS-485 | - | Two | 100 to
240 VAC |
E5EC-CR2ASM-804 | |
Linear current output | Relay output | 24 VAC/
VDC |
E5EC-CR2DSM-804 | ||||
Relay output (Open) * | Relay output
(Close) * |
- | - | - | - | 100 to
240 VAC |
E5EC-PR0ASM-800 |
Relay output (Open) * | Relay output
(Close) * |
Two | E5EC-PR2ASM-800 | ||||
Relay output (Open) * | Relay output
(Close) * |
RS-485 | Two | E5EC-PR2ASM-804 |
* Position proportional control model.
Note: Draw-out-type models of the E5EC-800 are available. Ask your OMRON representative for details.
(1) Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Model |
---|
E53-COV24 |
Model |
---|
Y92S-P9 |
Note: This Waterproof Packing is provided with the Digital Temperature Controller.
Model |
---|
Y92A-49N |
Model |
---|
Y92S-P7 |
Note: This Front Port Cover is provided with the Digital Temperature Controller.
Model |
---|
Y92F-51
(Two Adapters are included.) |
Note: This Mounting Adapter is provided with the Digital Temperature Controller.
Hole diameter | Model |
---|---|
5.8 mm | E54-CT1 |
5.8 mm | E54-CT1L * |
12.0 mm | E54-CT3 |
12.0 mm | E54-CT3L * |
* Lead wires are included with these CTs. If UL certification is required, use these CTs.
last update: October 2, 2017